The paper attempts to assess the possibility of using typical check structures equipped with sluice gates to measure the volumetric flow rate in the irrigation channels. The submerged flow through the sluice gate was considered. Experimental tests on a model of typical check structure in 1:2 scale were carried out. The conducted analyzes confirmed the possibility of using discharge equation for submerged flow through the sluice gate to estimate the water flow rate in the irrigation channels. In order to obtain accurate values of flow rate, the downstream tailwater depth should be measured at the appropriate distance from the sluice gate. For different values of gate-opening height, the downstream water depth measurement locations allowing for a correct flow estimation were indicated. This approach might be useful in calibration of other designs of sluice gates for flow measurements.
An analysis of energy efficiency for transcritical compression unit with CO2 (R744) as the refrigerant has been carried out using empirical operating characteristics for the two-phase ejector. The first stage of the refrigerant compression is carried out in the ejector. The criterion adopted for the estimation of energy efficiency for the cycle is the coefficient of performance COP. The analysis is performed for the heat pump and refrigeration systems. The results of COP for the systems with the ejector has been compared with the COPL values for the single stage Linde cycle.