There are typically two systems in use for sound reinforcement in open areas: the central, “wall of sound” system with speakers localized at the sides of the stage, and the zone system, in which additional speakers are introduced to obtain a uniform sound pressure level throughout the area of listening. In the past two decades the line array systems gained great popularity. The main purpose of their use is to obtain a uniformly distributed sound level throughout the listening area in order to achieve good speech intelligibility. The present paper aims to present an alternative and original method of sound reinforcement in open areas which is in contrast to the above solutions. This new method allows achieving a uniformly distributed sound pressure and good speech intelligibility in the area of interest, and also allows to gain spatial sound impression that accompanies sound reproduction in concert halls. Another advantage of the proposed system is the reduction of the sound level outside the area of interest, i.e. reduction of the noise level outside the area of listening.
One of the main issues of design process of HVAC systems and ventilation ducts in particular is correct modelling of coupling of the flow field and acoustic field of the air flowing in such systems. Such a coupling can be modelled in many ways, one of them is using linearised Euler equations (LEE). In this paper, the method of solving these equations using finite element method and open source tools is decribed. Equations were transformed into functional and solved using Python language and FEniCS software. The non-reflective boundary condition called buffer layer was also implemented into equations, which allowed modelling of unbounded domains. The issue, influence of flow on wave propagation, could be adressed using LEE equations, as they take non-uniform mean flow into account. The developed tool was verified and results of simulations were compared with analytical solutions, both in one- and two-dimensional cases. The obtained numerical results are very consistent with analytical ones. Furthermore, this paper describes the use of the developed tool for analysing a more complex model. Acoustic wave propagation for the backward-facing step in the presence of flow calculated using Navier-Stokes equations was studied.
Currently, overhead lines dominate in the Polish medium and low voltage distribution networks. Maintaining their high reliability constitutes a very important challenge, especially under the severely changing climate conditions. An overhead power line exposed to high ice and rime loads has been considered. Using the finite element method (FEM), mechanical reliability of the distribution infrastructure was examined under various atmospheric conditions. Loads under the stressful conditions of rime, ice and wind were determined for the weakest section of the 30 kV overhead line, which consisted of concrete poles and ACSR conductors. SAIDI and SAIFI reliability indices and costs were determined for several variants of object reconstruction. The results allowed for determination of a solution relying on relocating the cables of all lateral branches and main line ice protection, through a system based on a weather-coordinated increase of the electrical load. To verify the solution proposed, a field experiment was conducted. The experiment confirmed the effectiveness of the solution proposed that appears to be universal. The paper is a result of synergic cooperation of two academic teams, i.e. a mechanical and electrical power engineering one, and the distribution system operator (DSO).