@ARTICLE{Siekaniec_D._Effect_2017, author={Siekaniec, D. and Kopyciński, D. and Guzik, E. and Tyrała, E. and Nowak, A.}, volume={vol. 17}, number={No 2}, journal={Archives of Foundry Engineering}, howpublished={online}, year={2017}, publisher={The Katowice Branch of the Polish Academy of Sciences}, abstract={The present work, presented the study of effect of different inoculants on impact toughness in High Chromium Cast Iron. The molds were pouring in industrial conditions and samples were tested in laboratory in Faculty of Foundry Engineering at AGH. Seven samples were tested - one reference sample, three with different addition of Fe-Ti, and three with different addition of Al. The samples were subjected to impact toughness on Charpy hammer and the hardness test. The presented investigations indicate that for the each inoculant there is an optimal addition at which the sample obtained the highest value of impact toughness. For the Fe-Ti it is 0.66% and for Al is 0.17%. Of all the examined inoculants best results were obtained at a dose of 0.66% Fe-Ti. Titanium is a well-known as a good modifier but very interesting results gives the aluminum. Comparing the results obtained for the Fe-Ti and Al can be seen that in the case of aluminum hardness is more stable. The hardness of all samples is around 40-45 HRC, which is not high for this type of cast iron. Therefore, in future studies it is planned to carry out the heat treatment procedure that may improves hardness.}, type={Artykuły / Articles}, title={Effect of Different Inoculants on Impact Toughness in High Chromium Cast Iron}, URL={http://ochroma.man.poznan.pl/Content/102013/PDF/afe-2017-0056.pdf}, doi={10.1515/afe-2017-0056}, keywords={mechanical properties, High chromium cast iron, Inoculation, Impact toughness, hardness}, }