@ARTICLE{Fukuda_Kengo_A_2010, author={Fukuda, Kengo and Yoshida, Koji and Kinugasa, Tetsuya and Kamon, Morihito and Kagawa, Yoichiro and Ono, Toshiro}, number={No 2}, journal={Metrology and Measurement Systems}, pages={151-162}, howpublished={online}, year={2010}, publisher={Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation}, abstract={A checkweigher is an automatic machine to measure the weight of in-motion products. It is usually located around the end of the production process and ensures the weight of a product within specified limits. Any products are taken out of line if their weights are out of the specified limits. It is usually equipped with an optical device. It is used to make a trigger to set the time duration to allow a product to move completely on the weigh belt for sampling the weight. In this paper, a new method of mass measurement for checkweighers is proposed which uses just signal processing without the optical device. The effectiveness of the method is shown through experiments. Also a possibility of faster estimation of weight is shown.}, type={Artykuły / Articles}, title={A New Method of Mass Measurement for Checkweighers}, URL={http://ochroma.man.poznan.pl/Content/107045/PDF/Journal10178-VolumeXVII%20Issue2_02%20paper.pdf}, doi={10.2478/v10178-01-0014-8}, keywords={checkweigher, weighing method, signal processing, high accuracy}, }