@ARTICLE{Mickiewicz_Witold_Modified_2020, author={Mickiewicz, Witold and Raczyński, Michał}, volume={vol. 27}, number={No 1}, journal={Metrology and Measurement Systems}, pages={181-194}, howpublished={online}, year={2020}, publisher={Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation}, abstract={Sound intensity measurements using special sensors in a form of pressure-velocity and pressure-pressure probes are becoming more and more often the method of choice for characterization of sound sources. Its wider usability is blocked by the probes’ costs. This paper is on a possible modification of the well-known pressure-pressure sound intensity measurement method. In the proposed new approach a synchronized measurement procedure using only single microphone is used. The paper presents the basics of the sound intensity theory, a review of currently usedmethods of intensity measurement and requirements and limitations of the new method. In the proposed approach one microphone and a properly designed positioning system is used. The application of the method to study the directional characteristics of an active loudspeaker system have been described in detail. The obtained results were compared with those of measurements performed with a commercial p–u probe. The paper contains conclusions indicating advantages of the applied method in comparison with standard pressure measurement methods.}, type={Article}, title={Modified pressure-pressure sound intensity measurement method and its application to loudspeaker set directivity assessment}, URL={http://ochroma.man.poznan.pl/Content/115051/PDF/14_MMS_1_2020.pdf}, doi={10.24425/mms.2020.131720}, keywords={sound intensity, pressure-pressure intensity probe, loudspeaker set measurements}, }