@ARTICLE{Rajczyk_Rafał_Co-Combustion_2014, author={Rajczyk, Rafał and Bień, Jurand and Palka, Henryk and Pogodziński, Andrzej and Smorąg, Hubert}, volume={vol. 40}, number={No 3}, journal={Archives of Environmental Protection}, howpublished={online}, year={2014}, publisher={Polish Academy of Sciences}, abstract={According to data of the Central Statistical Office, the amount of sludge produced in municipal wastewater treatment plants in 2010 amounted to 526000 Mg d.m. The forecast of municipal sewage sludge amount in 2015 according to KPGO2014 will reach 642400 Mg d.m. and is expected to increase in subsequent years. Significant amounts of sludge will create problems due to its utilization. In order to solve this problem the use of thermal methods for sludge utilization is expected. According to the National Waste Management Plan nearly 30% of sewage sludge mass should be thermally utilized by 2022. The article presents the results of co-combustion of coal and municipal sewage sludge in a bubbling fluidized bed boiler made by SEFAKO and located in the Municipal Heating Company in Morag. Four tests of hard coal and sewage sludge co-combustion have been conducted. Boiler performance, emissions and ash quality were investigated.}, type={Artykuły / Articles}, title={Co-Combustion of Municipal Sewage Sludge and Hard Coal on Fluidized Bed Boiler WF-6}, URL={http://ochroma.man.poznan.pl/Content/85962/PDF/10265-Volume40-Issue3-paper_08.pdf}, doi={10.2478/aep-2014-0027}, keywords={Municipal sewage sludge, co-combustion, bubbling fluidized bed boiler}, }