Details

Title

Interpolated-DFT-Based Fast and Accurate Amplitude and Phase Estimation for the Control of Power

Journal title

Metrology and Measurement Systems

Yearbook

2016

Volume

vol. 23

Issue

No 1

Authors

Keywords

control of power ; grid signal ; amplitude and phase estimation ; renewable energy ; interpolated DFT ; maximum decay side-lobes windows

Divisions of PAS

Nauki Techniczne

Coverage

13-26

Publisher

Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation

Date

2016.03.30

Type

Artykuły / Articles

Identifier

DOI: 10.1515/mms-2016-0013 ; ISSN 2080-9050, e-ISSN 2300-1941

Source

Metrology and Measurement Systems; 2016; vol. 23; No 1; 13-26

References

Štremfelj (2013), Nonparametric estimation of power quantities in the frequency domain using Rife - Vincent windows on Instr and, IEEE Trans, 62, 2171. ; Yang (2013), Phase Compensation Resonant Controller for PWM Converters on, IEEE Trans Ind, 9, 957, doi.org/10.1109/TII.2012.2210432 ; Rife (1974), Single - Tone Parameter Estimation from Discrete - Time Observations on Inform Theory, IEEE Trans, 20. ; Kanieski (2013), Kalman Filter - Based Control System for Power Quality Conditioning Devices on, IEEE Trans Ind, 60, 5214, doi.org/10.1109/TIE.2012.2226412 ; Alhaj (2013), Power System Harmonics Estimation using Sliding Window Based LMS on Signal and Image Proc Applications, IEEE Intern Conf. ; Jain (2013), Fast Harmonic Estimation of Stationary and Time - Varying Signals Using EAAWNN on Instr and, IEEE Trans, 62, 335. ; Yamada (2013), High - Accuracy Estimations of Frequency Amplitude , and Phase With a Modified DFT for Asynchronous Sampling on Instr and, IEEE Trans, 62, 1428. ; Ray (2012), Ensemble - Kalman - Filter - Based Power System Harmonic Estimation on Instr and, IEEE Trans, 61, 3216. ; Rife (1970), Use of the Discrete Fourier Transform in the Measurement of Frequencies and Levels of Tones Tech, Bell Syst Journal, 49, 197, doi.org/10.1002/j.1538-7305.1970.tb01766.x ; Dash (2011), A Fast Recursive Algorithm for the Estimation of Frequency Amplitude , and Phase of Noisy Sinusoid on, IEEE Trans Ind, 58, 4847, doi.org/10.1109/TIE.2011.2119450 ; Eren (2013), Composite Nonlinear Feedback Control and Stability Analysis of a Grid - Connected Voltage Source Inverter With LCL Filter on, IEEE Trans Ind, 60, 5059, doi.org/10.1109/TIE.2012.2225399 ; Vazquez (2014), Adaptive Vectorial Filter for Grid Synchronization of Power Converters Under Unbalanced and / or Distorted Grid Conditions on, IEEE Trans Ind, 61, 1355, doi.org/10.1109/TIE.2013.2258302 ; Belega (2014), Fast Synchrophasor Estimation by Means of Frequency - Domain and Time - Domain Algorithms on Instr and, IEEE Trans, 63, 388. ; Borkowski (2014), Interpolated DFT - Based Fast and Accurate Frequency Estimation for the Control of Power on, IEEE Trans Ind, 61, 7026, doi.org/10.1109/TIE.2014.2316225 ; Fu (2013), Phase - Based , Time - Domain Estimation of the Frequency and Phase of a Single Sinusoid in AWGN - The role and Applications of the Additive Observation Phase Noise Model on Theory, IEEE Trans Inf, 59, 3175, doi.org/10.1109/TIT.2013.2238604 ; Shahbazi (2013), FPGA - Based Fast Detection With Reduced Sensor Count for a Fault - Tolerant Three - Phase Converter on, IEEE Trans Ind, 9, 1343, doi.org/10.1109/TII.2012.2209665 ; Chen (2013), A Phasor Estimator for Synchronization Between Power Grid and Distributed Generation System on, IEEE Trans Ind, 60, 3248. ; Huang (2010), MSE lower bounds for phase estimation based on overlapped Gaussian distribution on and Inform, Intern Symp Commun Techn. ; Belega (2008), Frequency estimation via weighted multipoint interpolated DFT and, IET Scien Tech, 2, 1, doi.org/10.1049/iet-smt:20070022 ; Rahim (2013), Energy policy to promote photovoltaic generation, Renew Energy Rev, 25, 44, doi.org/10.1016/j.rser.2013.03.030 ; Feola (2013), On the Effects of Unbalances , Harmonics and Interharmonics on PLL Systems on Instr and, IEEE Trans, 62, 2399. ; Nuttall (1981), Some Windows with Very Good Sidelobe Behavior on and Sig, IEEE Trans Proc, 29, 84. ; Borkowski (2014), Influence of A D Quantization in Interpolated - DFT - Based System of Power Control with Small Delay, Metrol Meas Syst, 21, 423, doi.org/10.2478/mms-2014-0036 ; Chen (2013), A Phasor Estimator for Synchronization Between Power Grid and Distributed Generation System on, IEEE Trans Ind, 60, 3248, doi.org/10.1109/TIE.2012.2198041 ; Kabir (2014), Coordinated Control of Grid - Connected Photovoltaic Reactive Power and Battery Energy Storage Systems to Improve the Voltage Profile of a Residential Distribution Feeder on, IEEE Trans Ind, 10, 967, doi.org/10.1109/TII.2014.2299336 ; Alhaj (2014), Power system harmonics estimation using LMS , LMF and LMS on Intel and Adv, Intern Conf Syst.
×