Szczegóły Szczegóły PDF BIBTEX RIS Tytuł artykułu Evaluation of portable blood glucose meters using canine and feline pooled blood samples Tytuł czasopisma Polish Journal of Veterinary Sciences Rocznik 2016 Numer No 4 Autorzy Mori, A. ; Oda, H. ; Onozawa, E. ; Shono, S. ; Takahashi, T. ; Yamashita, S. ; Fujimoto, H. ; Sako, T. Wydział PAN Nauki Biologiczne i Rolnicze Wydawca Polish Academy of Sciences Committee of Veterinary Sciences ; University of Warmia and Mazury in Olsztyn Data 2016 Identyfikator DOI: 10.1515/pjvs-2016-0089 ; ISSN 1505-1773 Źródło Polish Journal of Veterinary Sciences; 2016; No 4 Referencje Domori (2014), The clinical utility of two human portable blood glucose meters in canine and feline practice, Vet Clin Pathol, 43, 55, doi.org/10.1111/vcp.12115 ; Wess (2000), Capillary blood sampling from the ear of dogs and cats and use of portable meters to measure glucose concentration, J Small Anim Pract, 41, 60, doi.org/10.1111/j.1748-5827.2000.tb03164.x ; Freckmann (2012), System accuracy evaluation of blood glucose monitoring systems for self - monitoring of blood glucose according to DIN EN ISO, Diabetes Sci Technol, 6, 15197. ; Mori (2011), Evaluation of artificial pancreas technology for continuous blood glucose monitoring in dogs, J Artif Organs, 14, 133, doi.org/10.1007/s10047-011-0560-1 ; Wess (2000), a Assessment of five portable blood glucose meters for use in cats, Am J Vet Res, 61, 1587, doi.org/10.2460/ajvr.2000.61.1587 ; Barman (1993), Separation and size distribution of red blood cells of diverse size shape , and origin by flow / hyperlayer field - flow fractionation, Anal Biochem, 212. ; Brito (2014), ISO - based assessment of accuracy and precision of glucose meters in dogs, J Vet Intern Med, 28, 1405, doi.org/10.1111/jvim.12397 ; Higgins (1982), Glycosylated hemoglobin in human and animal red cells Role of glucose permeability, Diabetes, 31, 743, doi.org/10.2337/diab.31.9.743 ; Clarke (1987), Evaluating clinical accuracy of systems for self - monitoring of blood glucose, Diabetes Care, 10, 622, doi.org/10.2337/diacare.10.5.622 ; Cox (1997), Understanding error grid analysis, Diabetes Care, 20, 911, doi.org/10.2337/diacare.20.6.911 ; Johnson (2009), Comparison of a human portable blood glucose meter , veterinary portable blood glucose meter , and automated chemistry analyzer for measurement of blood glucose concentrations in dogs, J Am Vet Med Assoc, 235. ; Khositseth (2015), Accuracy of bedside glucometry in critically ill children with peripheral hypoperfusion, J Clin Monit Comput, 29, 145, doi.org/10.1007/s10877-014-9579-1 ; Rendell (1985), An interspecies comparison of normal levels of glycosylated hemoglobin and glycosylated albumin, Comp Biochem Physiol, 819. ; Magnani (1978), Comparative studies on red blood cell glucose phosphorylating activities of mammals, Comp Biochem Physiol, 323.