Details

Title

A New Method for Assessing Haemolysis in a Rotary Blood Pump Using Large Eddy Simulations (LES)

Journal title

Chemical and Process Engineering

Yearbook

2017

Volume

vol. 38

Issue

No 2

Authors

Keywords

rotary blood pump ; large eddy simulations ; haemolysis

Divisions of PAS

Nauki Techniczne

Coverage

231-239

Publisher

Polish Academy of Sciences Committee of Chemical and Process Engineering

Date

2017.06.30

Type

Artykuły / Articles

Identifier

DOI: 10.1515/cpe-2017-0022 ; ISSN 2300-1925 (Chemical and Process Engineering)

Source

Chemical and Process Engineering; 2017; vol. 38; No 2; 231-239

References

Bluestein (2017), Utilizing Computational Fluid Dynamics in cardiovascular engineering and medicine - What you need to know Its translation to the clinic / bedside, Artif organs, 41, 117, doi.org/10.1111/aor.12914 ; Leverett (1972), Red blood cell damage by shear stress, Biophys J, 12, 257, doi.org/10.1016/S0006-3495(72)86085-5 ; Wang (2008), Applications of traditional pump design theory to artificial heart and CFD simulation, Front Energy Power Eng China, 2, 504, doi.org/10.1007/s11708-008-0059-5 ; Sutera (1975), Deformation and fragmentation of human red blood cells in turbulent shear flow, Biophys J, 15, 1, doi.org/10.1016/S0006-3495(75)85787-0 ; Tavoularis (2003), Towards optimal control of blood flow in artificial hearts, Cardiovascular Eng, 8, 20, doi.org/10.1046/j.1525-1594.2003.00026.x ; Kim (1992), Numerical simulation of steady flow in a two - dimensional total artificial heart model, Biomech Eng, 114, 497, doi.org/10.1115/1.2894101 ; Germano (1991), A dynamic subgrid - scale eddy viscosity model Fluids A :, Phys Fluid Dyn, 3, 1760, doi.org/10.1063/1.857955 ; Bluestein (1969), Hemolytic effects of energy dissipation in flowing blood, Med Biol Eng Comput, 7, 1, doi.org/10.1007/BF02474665 ; Williams (1970), Hemolysis near a transversely oscillating wire, Science, 169, doi.org/10.1126/science.169.3948.871 ; Jones (1995), A relationship between Reynolds stresses and viscous dissipation : Implications to red cell damage, Ann Biomed Eng, 23, 21, doi.org/10.1007/BF02368297 ; Szwast (2012), Mathematical model for biological cell deformation in a cylindrical pore, Chem Process Eng, 33, 385, doi.org/10.2478/v10176-012-0034-x ; Smagorinsky (1963), General circulation experiments with the primitive equations The basic experiment, Mon Weather Rev, 91, doi.org/10.1175/1520-0493(1963)091 ; Arvand (2005), A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump, Artif Organs, 29, 531, doi.org/10.1111/j.1525-1594.2005.29089.x ; Leprince (2003), Bridge to transplantation with the Jarvik total artificial heart : A single - center - year experience Lung, Heart Transplant, 7, 1296. ; Saito (2005), Chronic nonpulsatile blood flow is compatible with normal end - organ function : Implications for LVAD development, Artif Organs, 8, 143, doi.org/10.1007/s10047-005-0295-y ; Nevaril (1968), Erythrocyte damage and destruction induced by shearing stress, Lab Clin Med, 71. ; Okamoto (2003), Blood compatible design of a pulsatile blood pump using computational fluid dynamics and computer aided design and manufacturing technology, Artif Organs, 27, 61, doi.org/10.1046/j.1525-1594.2003.07183.x ; Pohorecki (2001), Erythrocyte destruction during turbulent mixing, Biochem Eng J, 9, 147, doi.org/10.1016/S1369-703X(01)00135-8 ; Bałdyga (1995), Interpretation of turbulent mixing using fractals and multifractals, Chem Eng Sci, 50, 381, doi.org/10.1016/0009-2509(94)00217-F ; Mitamura (2011), A magnetic fluid seal for rotary blood pumps : effects of seal structure on long - term performance in liquid, Artif Organs, 14, 23, doi.org/10.1007/s10047-010-0526-8 ; Lilly (1992), A proposed modification of the Germano subgrid - scale closure method Fluids A :, Phys Fluid Dyn, 4, 633, doi.org/10.1063/1.858280 ; Moin (1982), Numerical investigation of turbulent channel flow, Fluid Mech, 118, 341, doi.org/10.1017/S0022112082001116 ; Apel (2001), Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics, Artif Organs, 25, 341, doi.org/10.1046/j.1525-1594.2001.025005341.x ; Yoganathan (2005), Flow in prosthetic heart valves : state - of - the - art and future directions, Ann Biomed Eng, 33, 1689, doi.org/10.1007/s10439-005-8759-z ; Bludszuweit (1995), Model for a general mechanical blood damage prediction, Artif Organs, 19, 583, doi.org/10.1111/j.1525-1594.1995.tb02385.x ; Rooney (1970), Hemolysis near an ultrasonically pulsating gas bubble, Science, 169, doi.org/10.1126/science.169.3948.869 ; Garatti (2008), Clinical outcome and bridge to transplant rate of left ventricular assist device recipient patients : comparison between continuous - flow and pulsatile - flow devices, Eur Cardiothorac Surg, 34, 275, doi.org/10.1016/j.ejcts.2008.02.019 ; Medvitz (2011), Computational fluid dynamics design and analysis of a passively suspended Tesla pump left ventricular assist device, Artif Organs, 35, 522, doi.org/10.1111/j.1525-1594.2010.01087.x ; Song (2003), Computational fluid dynamics prediction of blood damage in a centrifugal pump, Artif Organs, 27, 938, doi.org/10.1046/j.1525-1594.2003.00026.x ; Leonard (1975), Energy cascade in large - eddy simulations of turbulent fluid flows, Adv Geophys, 18, 237, doi.org/10.1016/S0065-2687(08)60464-1 ; Gregoriades (2000), Cell damage of microcarrier cultures as a function of local energy dissipation created by a rapid extensional flow, Biotech Bioeng, 69, 171, doi.org/10.1002/(SICI)1097-0290(20000720)69:2

Editorial Board

Editorial Board

Ali Mesbah, UC Berkeley, USA ORCID logo0000-0002-1700-0600

Anna Gancarczyk, Institute of Chemical Engineering, Polish Academy of Sciences, Poland ORCID logo0000-0002-2847-8992

Anna Trusek, Wrocław University of Science and Technology, Poland ORCID logo0000-0002-3886-7166

Bettina Muster-Slawitsch, AAE Intec, Austria ORCID logo0000-0002-5944-0831

Daria Camilla Boffito, Polytechnique Montreal, Canada ORCID logo0000-0002-5252-5752

Donata Konopacka-Łyskawa, Gdańsk University of Technology, Poland ORCID logo0000-0002-2924-7360

Dorota Antos, Rzeszów University of Technology, Poland ORCID logo0000-0001-8246-5052

Evgeny Rebrov, University of Warwick, UK ORCID logo0000-0001-6056-9520

Georgios Stefanidis, National Technical University of Athens, Greece ORCID logo0000-0002-4347-1350

Ireneusz Grubecki, Bydgoszcz Univeristy of Science and Technology, Poland ORCID logo0000-0001-5378-3115

Johan Tinge, Fibrant B.V., The Netherlands ORCID logo0000-0003-1776-9580

Katarzyna Bizon, Cracow University of Technology, Poland ORCID logo0000-0001-7600-4452

Katarzyna Szymańska, Silesian University of Technology, Poland ORCID logo0000-0002-1653-9540

Marcin Bizukojć, Łódź University of Technology, Poland ORCID logo0000-0003-1641-9917

Marek Ochowiak, Poznań University of Technology, Poland ORCID logo0000-0003-1543-9967

Mirko Skiborowski, Hamburg University of Technology, Germany ORCID logo0000-0001-9694-963X

Nikola Nikacevic, University of Belgrade, Serbia ORCID logo0000-0003-1135-5336

Rafał Rakoczy, West Pomeranian University of Technology, Poland ORCID logo0000-0002-5770-926X

Richard Lakerveld, Hong Kong University of Science and Technology, Hong Kong ORCID logo0000-0001-7444-2678

Tom van Gerven, KU Leuven, Belgium ORCID logo0000-0003-2051-5696

Tomasz Sosnowski, Warsaw University of Technology, Poland ORCID logo0000-0002-6775-3766



×