Details

Title

A hybrid (hydro-numerical) circulatory model: investigations of mechanical aortic valves and a numerical valve model

Journal title

Bulletin of the Polish Academy of Sciences Technical Sciences

Yearbook

2015

Volume

63

Issue

No 3

Authors

Divisions of PAS

Nauki Techniczne

Coverage

605-612

Date

2015[2015.01.01 AD - 2015.12.31 AD]

Identifier

DOI: 10.1515/bpasts-2015-0071 ; ISSN 2300-1917

Source

Bulletin of the Polish Academy of Sciences: Technical Sciences; 2015; 63; No 3; 605-612

References

Darowski (2013), A new hybrid ( hydro - numerical ) model of the circulatory system Bull :, Tech, 22, 993. ; Ge (2008), Characterization of hemodynamic forces induced by mechanical heart valves : Reynolds vs viscous stresses, Biomed Eng, 36, 276. ; Bach (2005), Ten year outcome after aortic valve replacement with the Freestyle stentless bioprosthesis, Thorac Surg, 80, 480, doi.org/10.1016/j.athoracsur.2005.03.027 ; Emery (2005), The St Jude medical cardiac valve prosthesis : a - year experience with a single valve replacement, Thorac Surg, 79, 776, doi.org/10.1016/j.athoracsur.2004.08.047 ; Vesely (1991), Analysis of the Medtronic Intact bioprosthesis valve : Effects of zero - pressure fixation, Surg, 101, 90. ; Wieting (1996), The Bjőrk - Shiley Delrin tilting disc heart valve : historical perspective design and need for scientific analyses after years, Heart Valve Dis, 2, 157. ; Bloomfield (2002), Choice of heart valve prosthesis, Heart, 583, doi.org/10.1136/heart.87.6.583 ; Nkomo (2006), Burden of valvular diseases : a population - based study, Lancet Online, 368. ; Simon (2010), Simulation of the three - dimensional hinge flow fields of a bileaflet mechanical heart valve under aortic conditions, Biomed Eng, 38, 841. ; David (2001), Late results of heart valve replacement with the Hancock II bioprosthesis, Surg, 121, 268. ; Kozarski (2010), Comprehensive models of cardiovascular and respiratory systems inPhysical and Hybrid Models : Impedance Conversions eds New York, Science Publ, 20, 226. ; Kandemir (2006), St Jude medical and carbomedics mechanical heart valves in the aortic position comparison of long - term results, Heart Inst, 19, 154. ; Kozarski (2010), Comprehensive models of cardiovascular and respiratory systems inPhysical and Hybrid Models : Impedance Conversions eds New York, Science Publ, 21, 218. ; Sansone (2012), The - Year durability of a Bjőrk - Shiley Delrin - disc aortic valve prosthesis, Heart Inst, 39, 284. ; Matthews (1998), The development of the Starr - Edwards heart valve, Heart Inst, 25, 282. ; Yoganathan (2004), Using computational fluid dynamics to examine the hemodynamics of artificial heart valves US, Cardiology, 1.
×