Details Details PDF BIBTEX RIS Title Biomechanical properties of the thin PVD coatings defined by red blood cells Journal title Bulletin of the Polish Academy of Sciences Technical Sciences Yearbook 2015 Volume 63 Issue No 3 Authors Trembecka-Wójciga, K. ; Major, B. ; Lackner, J.M. ; Major, R. ; Bruckert, F. ; Jasek, E. Divisions of PAS Nauki Techniczne Coverage 697-705 Date 2015[2015.01.01 AD - 2015.12.31 AD] Identifier DOI: 10.1515/bpasts-2015-0081 ; ISSN 2300-1917 Source Bulletin of the Polish Academy of Sciences: Technical Sciences; 2015; 63; No 3; 697-705 References Takaseya (2007), Aortic valve replacement with mm St Jude Medical prostheses for a small aortic root in elderly patients, Thorac Surg, 2050, doi.org/10.1016/j.athoracsur.2007.01.044 ; Dadsetan (2001), In vitro studies of platelet adhesion on laser - treated polyethylene terephtalate surface, Mater Res, 540. ; Borger (2006), Twenty - year results of the Hancock II bioprosthesis, J Heart Valve Dis, 16, 49. ; Varon (1998), Cone and plate ( let ) analyzer : monitoring glycoprotein IIb / IIIa antagonists and von Willebr and disease replacement therapy by testing platelet deposition under flow conditions, Heart J, 8, 135. ; Borger (2007), Stentless aortic valve reoperations : a surgical challenge, Thorac Surg, 20, 737, doi.org/10.1016/j.athoracsur.2007.04.061 ; Aagaard (2005), and Fifteen years clinical experience with the CarboMedics prosthetic heart valve, Heart Valve Dis, 14, 82. ; Stefanidis (2005), Cannie re - year experience with the ATS mechanical valve in the mitral position, Thorac Surg, 27, 1934, doi.org/10.1016/j.athoracsur.2005.01.002 ; Emery (2005), The St Jude Medical cardiac valve prosthesis : a - year experience with single valve replacement, Thorac Surg, 23, 25. ; Bach (2005), Ten - year outcome after aortic valve replacement with the freestyle stentless bioprosthesis, Thorac Surg, 22, 480, doi.org/10.1016/j.athoracsur.2005.03.027 ; Jones (1996), Methods for in vitro analysis of leukocyte adhesion under flow condition inWeir s Handbook of Experimental Immunology, Science, 9. ; Riess (2007), Hemodynamic performance of the medtronic mosaic porcine bioprosthesis up to ten years, Thorac Surg, 18, 1310, doi.org/10.1016/j.athoracsur.2006.07.034 ; Bottio (2004), Small aortic annulus : the hydrodynamic performances of five commercially available bileaflet mechanical valves, Cardiovasc Surg, 28, 457. ; Otto (1997), Dymanic blood cell contact with biomaterials : validation of a flow chamber system according to international standards, Mater Sci Mater Med, 8, 119, doi.org/10.1023/A:1018515001850 ; Seyfert (2002), In vitro hemocompatibility testing of biomaterials according to the ISO, Eng, 19, 10993. ; Yago (2006), Catch bonds govern adhesion through L - selectin at threshold shear, Cell Biology, 10, 166. ; Cohen (2002), Are stentless valves hemodynamically superior to stented valves ? A prospective randomized trial, Thorac Surg, 19, 767, doi.org/10.1016/S0003-4975(01)03338-0 ; Demilly (2006), Kinetics of yeast detechment from controlled stainless steel surfaces, Colloids Surf, 51. ; Huang (2003), Hemocompatibility of titanium oxide films, Biomaterials, 24, 2177, doi.org/10.1016/S0142-9612(03)00046-2 ; Mueller (2012), Dynamic in vitro hemocompatibility testing improving the signal tonoise ratio, Tech, 1. ; Lackner (2010), pulsed laser deposited coatings on polymers, Biomedizinische Technik, 55, 57, doi.org/10.1515/bmt.2010.001 ; Tominaga (2005), - year experience with the Carbomedics cardiac prosthesis, Ann Thorac Surg, 24, 10. ; Valfrè (2006), Clinical results of Hancock II versus Hancock Standard at long - term follow - up, Cardiovasc Surg, 15, 132. ; Totaro (2005), Edwards PERIMOUNT Magna bioprosthesis : a stented valve with stentless performance ?, Cardiovasc Surg, 1668. ; Lopez (2008), Does the use of stentless aortic valves in a subcoronary position prevent patient - prosthesis - mismatch for small aortic annulus, Surg, 21, 331.