Details

Title

Thirty-six pulse rectifier scheme based on zigzag auto-connected transformer

Journal title

Archives of Electrical Engineering

Yearbook

2016

Volume

vol. 65

Issue

No 1 March

Authors

Keywords

autotransformer ; harmonic suppression ; multipulse rectifier ; power quality

Divisions of PAS

Nauki Techniczne

Coverage

117-132

Publisher

Polish Academy of Sciences

Date

2016

Type

Artykuły / Articles

Identifier

DOI: 10.1515/aee-2016-0009 ; ISSN: 1427-4221 ; eISSN: 2300-2506

Source

Archives of Electrical Engineering; 2016; vol. 65; No 1 March; 117-132

References

Singh (2006), T - Connected Autotransformer - Based Pulse AC - DC Converter for Variable Frequency Induction Motor Drives on, IEEE Trans Energy Conversion, 24, 663, doi.org/10.1109/TEC.2006.875777 ; Oliveira (2009), Optimization of Multipulse Converters with Delta and Y - differential Connections Conference pp, Power Electronics, 901. ; Abdollahi (2015), Harmonic Mitigation using Pulse AC - DC Converter for Direct Torque Controlled Induction Motor Drives and, Journal of Applied Research Technology, 36, 135, doi.org/10.1016/S1665-6423(15)30012-2 ; Fernandes (2011), A Family of Autoconnected Transformers for and pulse Converters - Generalization for Delta and Wye Topologies on, IEEE Trans Power Electronics, 12, 2065, doi.org/10.1109/TPEL.2010.2102773 ; Qiu (2015), A delta - type autotransformer based pulse AC - DC converter of Electrical, Australian Journal Electronics Engineering, 36, 13. ; Abdollahi (2012), Study of delta / polygon - connected transformer - based pulse ac - dc converter for power quality improvement of, Archives Electrical Engineering, 36, 277. ; Abdollahi (2012), Pulse Doubling in Zigzag - Connected Autotransformer - Based Pulse AC - DC Converter for Power Quality Improvement of, Journal Electrical Engineering, 12, 357. ; Chen (2015), Pulse Doubling in AC - DC Converters Based on Zigzag Auto - Connected Transformer for Harmonic Mitigation of, International Journal Electrical Engineering, 22, 9. ; Kalpana (2010), Harmonic mitigator based on pulse ac - dc converter for switched mode power supply, IET Power Electronics, 12, 947, doi.org/10.1049/iet-pel.2009.0325 ; Abdollahi (2015), Design and Construction of a Polygon - Connected Autotransformer - Based Pulse AC - DC Converter for Power Quality Improvement in Retrofit Applications Bulletin of the Polish Academy of, Sciences, 36, 353. ; Singh (2007), Zigzag Connected Autotransformer Based Controlled AC - DC Converter for Pulse Multiplication International Symposium on Industrial Electronics pp, IEEE, 889. ; Singh (2007), A Novel Connected Autotransformer - Based Pulse AC - DC Converter for Harmonic Mitigation in Adjustable - Speed Induction - Motor Drives on Industrial, IEEE Trans Electronics, 18, 2500, doi.org/10.1109/TIE.2007.900332 ; Singh (2008), Star - Connected Autotransformer - Based Full - Wave AC - DC Converters of Emerging Electric, International Journal Power Systems, 9, 1. ; Singh (2008), DC converters for improving power quality : a review on, IEEE Trans Power Electronics, 23, 260, doi.org/10.1109/TPEL.2007.911880 ; Paice (1996), Power Electronic Converter Harmonics : Multipulse Methods for Clean Power Press, IEEE. ; Chen (2015), Zigzag Connected Autotransformer - Based pulse AC - DC Converter of Emerging Electric, International Journal Power Systems, 24, 23. ; Kalpana (2013), Autoconnected - Transformer - Based Pulse AC - DC Converter for Telecommunication Power Supply on Industrial, IEEE Trans Electronics, 20, 4178, doi.org/10.1109/TIE.2012.2210373 ; Singh (2007), Harmonic Mitigation in AC - DC Converters for Vector Controlled Induction Motor Drives on, IEEE Trans Energy Conversion, 22, 637, doi.org/10.1109/TEC.2007.899202 ; Singh (2008), A pulse ac - dc converter for line current harmonic reduction, IET Power Electronics, 28, 287, doi.org/10.1049/iet-pel:20070239 ; Abdollahi (2012), T - connected Autotransformer Based Pulse AC - DC Converter for Power Quality Improvement, Electrical Review Przeglad Elektrotechniczny, 36, 321. ; Garg (2009), pulse ac - dc converter for harmonic mitigation, IET Power Electronics, 24, 364, doi.org/10.1049/iet-pel.2008.0039 ; Nguyen (2012), Comparative analysis of the chosen fieldweakening methods for the Direct Rotor Flux Oriented Control drive system of, Archives Electrical Engineering, 61, 443. ; Singh (2010), Autoconnected transformer - based pulse ac - dc converter for power quality improvement in switched mode power supplies, IET Power Electronics, 18, 524. ; Nakhaee (2011), Simulation of Pulse Autotransformer based AC - DC Converter Employing Pulse Multiplication with Direct Torque Controlled Induction Motor Drive Load nd Drive Systems and Technologies Conference pp, Power Electronics, 24, 593. ; Singh (2006), Harmonic Mitigation Using Pulse AC - DC Converter in Vector - Controlled Induction Motor Drives on Power Delivery, IEEE Trans, 12, 1483. ; Singh (2007), An Improved Power - Quality Pulse AC - DC for Varying Loads on Power Delivery, IEEE Trans, 30, 1179.
×