Nauki Techniczne

Archives of Electrical Engineering

Zawartość

Archives of Electrical Engineering | 2023 | vol. 72 | No 3

Abstrakt

High-Temperature Proton-Exchange Membrane Fuel Cells (HT-PEMFCs) are a candidate for electrical energy supply devices in more and more applications. Most notably in the aeronautic industry. Before any use, an HT-PEMFC is preheated and after that supplied with its active gases. Only at this state, the diagnostics can be performed. A method of testing not requiring a complete start-up would be beneficial for many reasons. This article describes an extended version of the charging and discharging diagnostic method of HT-PEMFCs with no active gases. This extended approach is named “Test Without Active Gases” (TWAG). This paper presents original research on the influence of nitrogen temperature and pressure on the HT-PEMFC response to charging and discharging. A lumped-element model of an HT-PEMFC is also presented. A numerical result of using this model to recreate an experimentally obtained curve is also presented.
Przejdź do artykułu

Autorzy i Afiliacje

Wojciech Rosiński
1
ORCID: ORCID
Christophe Turpin
2
ORCID: ORCID
Andrzej Wilk
1
ORCID: ORCID

  1. Faculty of Electrical and Control Engineering, Gdansk University of Technology, Gabriela Narutowicza 11/12, 80-233 Gdansk, Poland
  2. Team GENESYS, Laboratioire LAPLACE, 118 Rte de Narbonne, 31077 Toulouse, France

Abstrakt

The paper discusses the methods for calculating the power parameters of a line start permanent magnet synchronous motor (LSPMSM). The calculations have been performed using the author’s specialized FEM software and professional FEM packages, ANSYS Maxwell and COMSOL Multiphysics. The author’s algorithm for solving equations of the electromagnetic field based on the FEM has been presented. The in-house software developed on this algorithm and professional software have been used to analyse the power parameters of the LSPMS motor. In addition, both calculation time and accuracy were analysed. The calculation results were compared to the measurement results.
Przejdź do artykułu

Autorzy i Afiliacje

Mariusz Barański
1
ORCID: ORCID

  1. Institute of Electrical Engineering and Electronics, Faculty of Control, Robotics and Electrical Engineering, Poznan University of Technology, Piotrowo 3A, 60-965 Poznan

Abstrakt

The article presents the results of laboratory measurements of Ud breakdown voltages in a high-voltage vacuum insulating system for different pressures, contact gaps, type of electrode contacts and type of residual gas inside the discharge chamber. First of all, the electrical strength of the discharge chamber with a contact system terminated with contact pads made of W 70Cu 30 and Cu 75Cr 25 material was compared for selected values of contact gaps. It was found that below a pressure of p = 3.0 x 10 -1 Pa the electrical strength reaches an approximately constant value for each of the set contact gaps d. Analytical relationships were determined to calculate this value for each of the contact pads used. Above a pressure of p = 3.0 x 10 -1 Pa, the measured values of Ud breakdown voltages decrease sharply. The values of breakdown voltages in the discharge chamber with residual gases in the form of air, argon, neon and helium were also determined for selected values of contact gaps d. Depending on the residual gases used, significant differences were noted in the values of pressure p at which the loss of insulating properties in the discharge chamber occurred. These values were 3.3 x 10 -1 Pa for argon, 4.1 x 10 -1 Pa for air, 6.4 x 10 -1 Pa for neon, and 2.55 x 10 0 Pa for helium, respectively.
Przejdź do artykułu

Autorzy i Afiliacje

Michał Lech
1
ORCID: ORCID
Paweł Węgierek
1
ORCID: ORCID

  1. Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, Nadbystrzycka 38A str., 20-618 Lublin, Poland

Abstrakt

At present, the back-propagation (BP) network algorithm widely used in the short-term output prediction of photovoltaic power stations has the disadvantage of ignoring meteorological factors and weather conditions in the input. The existing traditional BP prediction model lacks a variety of numerical optimization algorithms, such that the prediction error is large. The back-propagation (BP) neural network is easy to fall into local optimization thus reducing the prediction accuracy in photovoltaic power prediction. In order to solve this problem, an improved grey wolf optimization (GWO) algorithm is proposed to optimize the photovoltaic power prediction model of the BP neural network. So, an improved grey wolf optimization algorithm optimized BP neural network for a photovoltaic (PV) power prediction model is proposed. Dynamic weight strategy, tent mapping and particle swarm optimization (PSO) are introduced in the standard grey wolf optimization (GWO) to construct the PSO–GWO model. The relative error of the PSO–GWO–BP model predicted data is less than that of the BP model predicted data. The average relative error of PSO–GWO–BP and GWO–BP models is smaller, the average relative error of PSO–GWO–BP model is the smallest, and the prediction stability of the PSO–GWO–BP model is the best. The model stability and prediction accuracy of PSO–GWO–BP are better than those of GWO–BP and BP.
Przejdź do artykułu

Autorzy i Afiliacje

Ping He
1
ORCID: ORCID
Jie Dong
1
ORCID: ORCID
Xiaopeng Wu
1
ORCID: ORCID
Lei Yun
1
ORCID: ORCID
Hua Yang
1
ORCID: ORCID

  1. Zhengzhou University of Light Industry, College of Electrical and Information Engineering, China

Abstrakt

Different buried permanent magnet arrangements in rotors are compared based on electrical machines found in literature regarding high-speed capability. An analytical approach is presented to analytically calculate mechanical stresses in the bilateral and central bridge of V arrangements in order to determine the achievable circumferential velocity of a rotor geometry. The mechanical model is coupled to an analytical model which can determine the flux density in the main air gap under consideration of flux leakage within the rotor. The multi-domain model enables the analytical design of high-speed rotors with buried permanent magnets in V-arrangement.
Przejdź do artykułu

Autorzy i Afiliacje

Maximilian Lauerburg
1
ORCID: ORCID
Polkrit Toraktrakul
1
Kay Hameyer
1
ORCID: ORCID

  1. Institute of Electrical Machines (IEM), RWTH Aachen UniversitySchinkelstr. 4, D-52062 Aachen, Germany

Abstrakt

The problem of lithium-ion cells, which degrade in time on their own and while used, causes a significant decrease in total capacity and an increase in inner resistance. So, it is important to have a way to predict and simulate the remaining usability of batteries. The process and description of cell degradation are very complex and depend on various variables. Classical methods are based, on the one hand, on fitting a somewhat arbitrary parametric function to laboratory data and, on the other hand, on electrochemical modelling of the physics of degradation. Alternative solutions are machine learning ones or nonparametric ones like support-vector machines or the Gaussian process (GP), which we used in this case. Besides using the GP, our approach is based on current knowledge of how to use non-parametric approaches for modeling the electrochemical state of batteries. It also uses two different ways of dealing with GP problems, like maximum likelihood type II (ML-II) methods and the Monte Carlo Markov Chain (MCMC) sampling.
Przejdź do artykułu

Autorzy i Afiliacje

Adrian Dudek
1
ORCID: ORCID
Jerzy Baranowski
1
ORCID: ORCID

  1. Department of Automatic Control and Robotics, AGH University of Science and Technology, Kraków, Poland

Abstrakt

This paper presents a novel fault detection algorithm for a three-phase interleaved DC–DC boost converter integrated in a photovoltaic system. Interleaved DC–DC converters have been used widely due to their advantages in terms of efficiency, ripple reductions, modularity and small filter components. The fault detection algorithm depends on the input current waveform as a fault indicator and does not require any additional sensors in the system. To guarantee service continuity, a fault tolerant topology is achieved by connecting a redundant switch to the interleaved converter. The proposed fault detection algorithm is validated under different scenarios by the obtained results.
Przejdź do artykułu

Autorzy i Afiliacje

Bilal Boudjellal
1
ORCID: ORCID
Tarak Benslimane
1
ORCID: ORCID

  1. Laboratory of Electrical Engineering, University of M’sila, Seat of the wilaya of M’sila, M’sila 28000, Algeria

Abstrakt

Gapped magnetic components are inherent to applications where conversion of power would force magnetic flux density beyond the saturation point of magnetic materials. A physical discontinuity in a magnetic path, which an air gap represents, signifies a drastic change in its reluctance to magnetic flux. This gives rise to a phenomenon referred to as the fringing effect, which impacts the performance of magnetic components. The fringing flux also affects the physical properties of magnetic components, such as magnetic reluctance and inductance. Since inductance of gapped magnetic components is a function of the size of the air gap, a relatively simple change to the configuration of the air gap or splitting a single gap into a plurality of gaps entails, frequently, a radical change to the magnetic circuit of the component. This paper examines the way the air-gap configuration affects the distribution of the fringing flux and, by extension, magnetic reluctance and inductance. A method to aid the design of multigap inductors is presented based on 3-D electromagnetic modelling as well as measurements. An analytic expression, which closely approximates the required length of quasi-distributed gaps substituting a single gap, is developed.
Przejdź do artykułu

Autorzy i Afiliacje

Rafal Kasikowski
1
ORCID: ORCID

  1. Institute of Electronics, Lodz University of Technology, 93-590 Lodz, Poland

Abstrakt

The effective design of energy-saving electric motors with efficiency class IE4 and higher requires the use of material characteristics that take into account the core shaping process. Therefore, it becomes necessary to use analytical or numerical models that take into account the change of local properties of Fe-Si material. The aim of the work is to indicate a useful analytical model for estimating the local magnetic permeability of the material, as well as to understand the reasons for these changes. For this purpose, low-loss ferromagnetic materials cut with a guillotine and a laser were tested. Rectangular samples, cut at an angle of 0 degrees in relation to the rolling direction, were subjected to macroscopic and microscopic examinations. Finally, the main reasons for changes in material characteristics for both cutting technologies were indicated. Therefore, the proposed model takes into account not only the cutting technology used, but also the current width of the tested strip, for which the material characteristics are to be determined. The parameters of the analytical model are determined on the basis of a limited number of measurements carried out on samples of a simple geometric shape.
Przejdź do artykułu

Autorzy i Afiliacje

Zbigniew Gmyrek
1
ORCID: ORCID
Barbara Kucharska
2
ORCID: ORCID

  1. Institute of Mechatronics and Information Systems, Lodz University of Technology, Stefanowskiego 22, 90-537 Łódz, Poland
  2. Department of Materials Engineering, Czestochowa University of Technology, Al. Armii Krajowej 19, 42-201 Czestochowa, Poland

Abstrakt

Commutation reactance is an important component in the voltage-source converter- based high-voltage direct current (VSC–HVDC) transmission system. Due to its connection to the converter, when there is a fault occurring on the valve-side bushing of a converter transformer, the nonlinearity operation of the converter complicates the characteristics of current flowing through commutation reactance, which may lead to maloperation of its overcurrent protection. It is of great significance to study the performance of commutation reactance overcurrent protection under this fault condition and propose corresponding improvement measures to ensure the safe and stable operation of AC and DC systems. In the VSC–HVDC system with the pseudo-bipolar structure of a three-phase two-level voltage source converter, the valve has six working periods in a power frequency cycle, and each period is divided into five working states. According to the difference between the fault phase and non-fault phase of the conductive bridge arms at the time of fault occurrence, these five working states are merged into two categories. On this basis, various faults of the valve-side bushing of a converter transformer are analyzed, and the conclusion is drawn that the asymmetric fault of valve-side bushing can lead to the maloperation of the commutation reactance overcurrent protection. Based on the characteristics that the current flowing through the commutation reactance after the asymmetric fault of the valve-side bushing contains decaying aperiodic components in addition to the fundamental frequency wave, a scheme to prevent the maloperation of commutation reactance overcurrent protection is proposed, which uses the unequal of two half cycle integral values with different starting points to realize the blocking of commutation reactance overcurrent protection, and it makes up the deficiency of existing protection in this aspect. Finally, this paper builds a VSC–HVDC system simulation model in the PSCAD/EMTDC platform to verify the effectiveness of the scheme.
Przejdź do artykułu

Autorzy i Afiliacje

Yanxia Zhang
1
Guanghao Dong
1
ORCID: ORCID
Le Wei
1
Jinting Ma
1
Shanshan Du
1

  1. School of Electrical and Information Engineering, Tianjin University, No. 92 Weijin Road, Nankai District, Tianjin, China

Abstrakt

Transmission lines’ live working is one of an effective means to ensure the reliable operation of transmission lines. In order to solve the unsafe problems existing in the implementation of traditional live working, the paper uses ground-based lidar to collect point cloud data. A tile based on the pyramid data structure is proposed to complete the storage and calling of point cloud data. The improved bidirectional filtering algorithm is used to distinguish surface features quickly and obtain a 3D model of the site. Considering the characteristics of live working, the speed of data reading and querying, the nearest point search algorithm based on octree is used to acquire a real- time calculation of the safe distance of each point in the planned path, and the safety of the operation mode is obtained by comparing with the value specified in the regulation, and assist in making decisions of the operation plan. In the paper, the simulation of the actual working condition is carried out by taking the “the electric lifting device ascending” as an example. The experimental results show that the established three-dimensional model can meet the whole process control of the operation, and has achieved practical effect.
Przejdź do artykułu

Autorzy i Afiliacje

Ying Wang
1
ORCID: ORCID
Haitao Zhang
1 2 3
Qiang Lv
3
Qiang Gao
3
Mingxing Yi
3

  1. School of Automation & Electrical Engineering, Lanzhou Jiaotong University, Gansu, China
  2. Key Laboratory of Opto-Electronic Technology and Intelligent Control Ministry of Education, Lanzhou Jiaotong University Gansu, China
  3. The UHV Company of State Grid Gansu Electric Power Company, Gansu, China

Abstrakt

The problem of large speed loss exists in the traditional passing through the electric phase-separation method of trains, which is more prominent when trains pass through an electric phase-separation zone in the uphill section of long ramps and may lead to the trains not passing through the phase-separation zone safely. In order to solve this problem, based on the energy storage type railroad power conditioner, a train uninterrupted phase-separation passing system based on the energy storage type railroad power conditioner is proposed. The energy storage railroad power conditioner can realize the recovery and utilization of regenerative braking energy of the electrified railroad. In the structure of the energy storage railroad power conditioner, the single-phase inverter is led from the middle DC side of the energy storage railroad power conditioner and connected to the neutral line through theLCLfilter and the step-up transformer, which constitutes an uninterrupted phaseseparation passing system. The single-phase inverter is controlled using virtual synchronous generator technology, which allows the single-phase inverter to have external characteristics similar to those of a synchronous generator, providing support for the voltage and frequency in the neutral zone. The power required by the train to pass the electric phase-separation is provided by the power supply arm or the energy storage system, which not only improves the utilization rate of regenerative braking energy but also realizes the uninterrupted phaseseparation passing of the train through the control of the voltage in the neutral region.
Przejdź do artykułu

Autorzy i Afiliacje

Ying Wang
1
ORCID: ORCID
Huan Yang
1
Xiaoqiang Chen
1
Ya Guo
2

  1. School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, 730070 China
  2. School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, 730070, China

Abstrakt

This paper studies the influence of different cooling technologies on the power density of a traction machine for heavy-duty distribution transport. A prototype induction machine is built with a housing cooling jacket, potted end-windings, entire winding cooling, and shaft cooling. Electromagnetic finite element and thermal lumped-parameter models are parameterized and verified using test bench measurements. The influence of each thermal resistance along the heat paths is studied and discussed. The results are used for studying different cooling technologies. The results indicate an improvement of the continuous power density up to 108% using shaft cooling and up to 15.6% using entire winding cooling.
Przejdź do artykułu

Autorzy i Afiliacje

Benedikt Groschup
1
ORCID: ORCID
Daniel Butterweck
1
Kay Hameyer
1
ORCID: ORCID

  1. Institute of Electrical Machines (IEM), RWTH Aachen University, Schinkelstraße 4, 52062 Aachen, Germany

Abstrakt

A microgrid is an appropriate concept for urban areas with high penetration of renewable power generation, which improves the reliability and efficiency of the distribution network at the consumer premises to meet various loads such as domestic, industrial, and agricultural types. Microgrids comprising inverter-based and synchronous generator-based distribution generators can lead to the instability of the system during the islanded mode of operation. This paper presents a study on designing stable microgrids to facilitate higher penetration of solar power generation into a distribution network. Ageneralized small signal model is derived for a microgrid with static loads, dynamic loads, energy storages, solar photovoltaic (PV) systems, and diesel generators, incorporating the features of dynamic systems. The model is validated by comparing the transient curves given by the model and a transient simulator subjected to step changes. The result shows that full dynamic models of complex systems of microgrids can be built accurately, and the proposed microgrid is stable for all the considered loading situations and solar PV penetration levels according to the small signal stability analysis.
Przejdź do artykułu

Autorzy i Afiliacje

W.E.P. Sampath Ediriweera
1
N.W.A. Lidula
1
H. Dayan B.P. Herath
2

  1. Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka
  2. Colombo City, Ceylon Electricity Board, Sri Lanka

Abstrakt

The grid integration of large-scale wind power will alter the dynamic characteristics of the original system and the power distribution among synchronous machines. Meanwhile, the interaction between wind turbines and synchronous machines will affect the damping oscillation characteristics of the system. The additional damping control of traditional synchronous generators provides an important means for wind turbines to enhance the damping characteristics of the system. To improve the low frequency oscillation characteristics of wind power grid-connected power systems, this paper adds a parallel virtual impedance link to the traditional damping controller and designs a DFIG-PSS-VI controller. In the designed controller, the turbine active power difference is chosen as the input signal based on residual analysis, and the output signal is fed back to the reactive power control loop to obtain the rotor voltage quadrature component. With DigSILENT/PowerFactory, the influence of the controller parameters is analyzed. In addition, based on different tie-line transmission powers, the impact of the controller on the low-frequency oscillation characteristics of the power system is examined through utilizing the characteristic root and time domain simulation analysis.
Przejdź do artykułu

Autorzy i Afiliacje

Ping He
1
ORCID: ORCID
Yongliang Zhu
2
Qiuyan Li
3
Jiale Fan
1
Yukun Tao
1

  1. Zhengzhou University of Light Industry, College of Electrical and Information Engineering, China
  2. Zhengzhou University of Light Industry, College of Materials and Chemical Engineering, China
  3. State Grid Henan Electric Power Company, Economic and Technical Research Institute, China

Abstrakt

Fault diagnosis and condition monitoring of synchronous machines running under load is a key determinant of their lifespan and performance. Faults such as broken rotor bars, bent shafts and bearing issues lead to eccentricity faults. These faults if not monitored may lead to repair, replacement and unforeseen loss of income. Researchers who attempted to investigate this kind of machine stopped at characterizing and deduced ways, types and effects of rotor eccentricity fault on the machine inductances using the winding function method. A modified closed-form analytical model of an eccentric synchronus reluctance motor (SynRM) is developed here taking into cognizance the machine dimensions and winding distribution for the cases of a healthy and unhealthy SynRM. This paper reports the study the SynRM under static rotor eccentricity using the developed analytical model and firming up the model with finite element method (FEM) solutions. These methods are beneficial as they investigated and presented the influence of the degrees of static eccentricity on the machine performance indicators such as speed, torque and the stator
current and assess the extent to which the machine performance will deteriorate when running with and without load. The results show that static eccentricity significantly affects the machine’s performance as the degree of eccentricity increases.
Przejdź do artykułu

Autorzy i Afiliacje

Emmanuel Idoko
1
Gideon David Umoh
2
Pauline Ijeoma Obe
3
Benjamin Okwudili Mama
4
Emeka Simon Obe
5

  1. Department of Electrical and Electronics Engineering, Federal University of Agriculture, 970101 Makurdi, Benue State, Nigeria
  2. Department of Electrical Engineering, Maritime Academy, 523101 Oron, Akwa Ibom State, Nigeria
  3. Department of Industrial Technical Education, University of Nigeria, 410001 Nsukka, Enugu State, Nigeria
  4. Department of Civil Engineering, University of Nigeria, 410001 Nsukka, Enugu State, Nigeria
  5. Department of Electrical, Electronic and Telecommunications Engineering, Botswana International University of Science and Technology, Plot 10071 Boseja, Palapye, Botswana

Instrukcja dla autorów

ARCHIVES OF ELECTRICAL ENGINEERING (AEE) (previously Archiwum Elektrotechniki), quarterly journal of the Polish Academy of Sciences is OpenAccess, publishing original scientific articles and short communiques from all branches of Electrical Power Engineering exclusively in English. The main fields of interest are related to the theory & engineering of the components of an electrical power system: switching devices, arresters, reactors, conductors, etc. together with basic questions of their insulation, ampacity, switching capability etc.; electrical machines and transformers; modelling & calculation of circuits; electrical & magnetic fields problems; electromagnetic compatibility; control problems; power electronics; electrical power engineering; nondestructive testing & nondestructive evaluation.

Manuscript submission:

All manuscripts should be submitted electronically on Editorial System.

Submission of paper to the Archives of Electrical Engineering is understood to imply that the article is original, unpublished and is not being considered for publication elsewhere. All articles will be reviewed. Since 2013, Authors wishing to use the facility of colour printing should consult the editors.

Template:

Microsoft Word is recommended as a standard word processor to prepare the paper to the AEE journal. If you use the LaTex format, please transfer your document to Microsoft Word and then use Template AEE.

While editing your paper, make sure that all the mathematical characters (symbols, identifiers, variables, vectors, axis marks, etc.) have the required shape, thickness, and slant kept throughout the whole article. The same appearance of a given mathematic character must be retained regardless of its place (text, equations, tables or figures).

The articles that don’t conform to the above will not be processed and published.

The reviewing process:

Each paper submitted for publication in Archives of Electrical Engineering is subjected to the following review procedure:

a) the paper is reviewed by the editor in chief or guest editor for general suitability for publication in AEE

b) if it is judged suitable two reviewers are selected and a double blind peer review process takes place

c) based on the recommendations of the reviewers, the editor then decides whether the paper should be accepted in its present form, revised or rejected

d) the author(s) is(are) informed by e-mail on the results of the reviewing procedure.

The papers are published on average within 3 months after acceptance.

Requirements for preparation of manuscripts:

The manuscript submitted for publication should have no less than 12 pages and no more than 16 pages. In the case of the manuscript longer than 16 pages, please contact the AEE Editorial Board before submitting your paper. The manuscripts, written in UK English, should be typed using Template AEE according to the following instructions and should include: a title page with the title of a manuscript, a short title; abstract; key words, text; list of references. A DOI number as well as received and revised data will be completed by Editor. When you open Template.doc, select "Print Layout" from the "View" menu in the menu bar (View > Print Layout). Then type over sections of Template.doc or cut and paste from another document and then use markup styles (Home > Styles). For example, the style at this point in the document is "main text").

All papers submitted for publication are assessed on the basis of the mutual anonymity rule as to the names of reviewers and authors. Authors' names and affiliations should not appear in the attached text/tables/figures.

If English is not your first language, ask an English-speaking colleague to proofread your manuscript. The manuscripts that fail to meet basic standards of literacy are likely to be immediately declined or after the language assessment, sent to the authors for linguistic improvement.

The manuscripts are published on average within 3 months after their acceptance.

Do not change the font sizes or line spacing to squeeze more text into a limited number of pages. Leave some open space around your figures.

The AEE journal publishes an ORCID for all authors. You will need a registered ORCID in order to submit your paper for peer review. ORCID registration is free and only takes a minute. Please note that ORCIDs will be added in the course of the author's proofreads.

Text:

The pages must be numbered consecutively. Articles should be divided into numbered sections, and if necessary subsections, preferably: Introduction, Material, Methods, Results, Conclusion and References. Any special characters (e.g. Greek, script, etc.) should be named in the margin where the character first occurs in the text. Names of species are to be accentuated with wavy underlining (italics). Equations should be numbered serially (1), (2), ... on the right side of the page. Footnotes should be avoided, if required, they should be used only for brief notes which do not fit well into the text. Figures and tables have to be included into the text. If table is typed on a separate page its position in the text should be marked. Abbreviations should be explained when they first appear in the text.

Math:

Please use the MathML editor as well as MathType editor to build an equation in your manuscript.

Equations:

Equations should be typed within the text, centred, and should be numbered consecutively throughout the text. Their numbers should be typed in parentheses, flush right. Equations should be referred to in text, e.g. (1), except at the beginning of a sentence: "Equation (1) is ...". All symbols appearing in equations have to be defined in the text, before or just after the equation.

If the symbols are written in Times New Roman use italic fonts. Symbols of vectors and matrices should be written in bold fonts. Do not italicize Greek fonts and mathematical symbols like e.g.: the derivative symbol d, max, min, etc. The indices of symbols that are indices themselves should be written in a clear manner.

Note that the equation is centered using a center tab stop. Please keep the same font in the formulas and text.

Unit Symbols, Abbreviations:

Define abbreviations and acronyms the first time they are used in the text, even after they have been defined in the abstract. Abbreviations such as IEEE, SI, MKS, CGS, sc, dc, and rms do not have to be defined. Do not use abbreviations in the title or heads unless they are unavoidable.

Si units are recommended for use in formulas, drawings and tables., for example the SI unit for magnetic field strength H is A/m. Apply the center dot to separate compound units.

Do not mix complete spellings and abbreviations of units: "Wb/m2" or "webers per square meter," not "webers/m2." Spell units when they appear in text: "...a few henries…", not "...a few H…".

Use a zero before decimal points: "0.25," not ".25." Use "cm3," not "cc."

Unit Symbols, SI Prefixes as well as Abbreviations should be writing in accordance with the IEEE standard

Tables, figures (illustrations) and captions:

The illustrations (line diagrams and photographs) should be suitable for direct reproduction. The lettering as well the details should have proportional dimensions to maintain their legibility after the usual reduction. All illustrations should be numbered consecutively (Fig. X). Tables are numbered with Arabic numerals.

All figures, figure captions, and tables in the text must be inserted into the correct places.

Figures, photos, tables or other parts of a manuscript that have previously appeared in another publication or are not the property of the authors must be properly acknowledged in the manuscript. Permission to republish these items must be obtained by the corresponding author from a person or institution holding the copyright, usually the publisher.

Authors are requested to send all drawings used in the article in additional files. Create a separate file for each image. Images should be submitted in a bitmap format (.jpeg) or/and in a vector format (.eps, .pdf or .cdr). Each file must be saved according to the number in the original article, e.g.: FIG1.JPG, FIG2.EPS, or FIG3.PDF. Bitmap illustrations must be “flattened”, which means no additional layers, for example, covering old descriptions.

Photographs, colour, and greyscale figures should be at least at a resolution of 400 dpi.

All colour figures should be generated in the RGB or CMYK colour space, while greyscale images in the greyscale colour space.

When preparing your figures/graphics etc., we suggest the use of the Arial 8 point font for axis numbers and Arial 9 point font for axis names. Figures/graphics etc. can be prepared in one of two proposed ways - see Template AEE.

Tables are numbered with Arabic numerals. Use 9 point Times New Roman for the title of the table and 9 point Times New Roman for the filling of the table (9 in the case of symbols with subscripts).

AEE journal allows an author to publish color figures in e-version at no charge, and automatically convert them to grayscale for print versions. Authors wishing to use the facility of color printing should consult the editors.

Conclusions:

A conclusion might elaborate on the importance of the work or suggest applications and extensions. Although a conclusion may review the main points of the manuscript, do not replicate the abstract as the conclusion.

References:

References in text must be numbered consecutively by Arabic numerals placed in square brackets. Please make sure that you use full names of journals i.e. Archives of Electrical Engineering. Please ensure that all references in the Reference list are cited in the text and vice versa.

Please provide name(s) and initials of author(s), the title of the manuscript, editors (if any), the title of the journal or book, a volume number, the page range, and finally the year of publication in brackets.

You can use the rules presented on the site: IEEE standard.

Examples of the ways in which references should be cited are given below:

Journal manuscript

[1] Author1 A., Author2 A., Title of paper, Title of periodical, vol. x, no. x, pp. xxx-xxx (YEAR).

example

[1] Steentjes S., von Pfingsten G., Hombitzer M., Hameyer K., Iron-loss model with consideration of minor loops applied to FE-simulations of electrical machines, IEEE Transactions on Magnetics. vol. 49, no. 7, pp. 3945-3948 (2013).

[2] Idziak P., Computer Investigation of Diagnostic Signals in Dynamic Torque of Damaged Induction Motor, Electrical Review (in Polish), to be published.

[3] Cardwell W., Finite element analysis of transient electromagnetic-thermal phenomena in a squirrel cage motor, submitted for publication in IEEE Transactions on Magnetics.

Conference manuscript

[4] Author A., Title of conference paper, Unabbreviated Name of Conf., City of Conf., Country of Conf., pp. xxx-xxx (YEAR).

example

[4] Popescu M., Staton D.A., Thermal aspects in power traction motors with permanent magnets, Proceedings of XXIII Symposium Electromagnetic Phenomena in Nonlinear Circuits, Pilsen, Czech Republic, pp. 35-36 (2016).

Book, book chapter and manual

[5] Author1 A., Author2 A.B., Title of book, Name of the publisher (YEAR).

example

[5] Zienkiewicz O., Taylor R.L., Finite Element method, McGraw-Hill Book Company (2000).

Patent

[6] Author1 A., Author2 A., Title of patent, European Patent, EP xxx xxx (YEAR).

example

[6] Piech Z., Szelag W., Elevator brake with magneto-rheological fluid, European Patent, EP 2 197 774 B1 (2011).

Thesis

[7] Author A., Title of thesis, PhD Thesis, Department, University, City of Univ. (YEAR).

example

[7] Driesen J., Coupled electromagnetic-thermal problems in electrical energy transducers, PhD Thesis, Faculty of Applied Science, K.U. Leuven, Leuven (2000).

For on electronic forms

[8] Author A., Title of article, in Title of Conference, record as it appears on the copyright page], © [applicable copyright holder of the Conference Record] (copyright year), doi: [DOI number].

example

[8] Kubo M., Yamamoto Y., Kondo T., Rajashekara K., Zhu B., Zero-sequence current suppression for open-end winding induction motor drive with resonant controller,in IEEE Applied Power Electronics Conference and Exposition (APEC), © APEC (2016), doi: 10.1109/APEC.2016.7468259

Website

[9] http://www.aee.put.poznan.pl, accessed April 2010.

Proofs:

Authors will receive proofs for correction, which should be returned promptly. All joint contributions must indicate the name and address of the authors to whom proofs should be sent.

Fees for printing the papers in Archives of Electrical Engineering:

AEE is published in Open Access, which means that all articles are available on the internet to all users immediately upon publication free of charge for the readers. Authors will be asked to a declaration that they are ready to cover the costs of printing their article.

The fee for the publication of an article in the AEE journal is 200 Euro.

Abstracting & Indexing:

Archives of Electrical Engineering is covered by the following services:

  • Arianta
  • Baidu Scholar
  • BazTech
  • Celdes
  • CNKI Scholar (China National Knowledge Infrastucture)
  • CNPIEC
  • DOAJ
  • EBSCO - TOC Premie
  • EBSCO (relevant databases)
  • EBSCO Discovery Service
  • Elsevier - Compendex
  • Elsevier - Engineering Village
  • Elsevier - SCOPUS
  • Genamics JournalSeek
  • Google Scholar
  • ICI Journals Master List
  • Inspec
  • J-Gate
  • Naviga (Softweco)
  • POL-Index
  • Primo Central (ExLibris)
  • ProQuest - Advanced Technologies Database with Aerospace
  • ProQuest - Electronics and Communications Abstracts
  • ProQuest - Engineering Journals
  • ProQuest - High Tech Research Database
  • ProQuest - Illustrata: Technology
  • ProQuest - SciTech Journals
  • ProQuest - Technology Journals
  • ProQuest - Technology Research Database
  • SCImago (SJR)
  • Summon (Serials Solutions/ProQuest)
  • TDOne (TDNet)
  • TEMA Technik und Management
  • Thomson Reuters - Emerging Sources Citation Index
  • Ulrich's Periodicals Directory/ulrichsweb
  • WorldCat (OCLC)

Preparation of manuscript for Archives of Electrical Engineering (AEE)

AEE License to publish

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji