Nauki Techniczne

Archives of Electrical Engineering

Zawartość

Archives of Electrical Engineering | 2024 | vol. 73 | No 3

Abstrakt

Radiofrequency (RF) ablation is a popular therapeutic technique for heating solid tumors that are medically unsuitable for resection or other treatments. Thermal ablation applicators create high-frequency electromagnetic fields (EMFs) within the tumor site, which causes heating, coagulation, and ultimately death of the cancer cells. The aim of this study is the numerical analysis of the temperature distributions, ablation zones, and specific absorption rates (SAR) during RF ablation in relation to an ellipsoidal shaped tumor placed in the model of liver tissue. The source of heat is a three-element system of RF needle applicators operating at a frequency 100 kHz, with a given electrode potential, inserted into the tumor. In order to obtain an appropriate temperature distribution in the target area, the Laplace equation coupled with the Pennes equation were solved using the finite element method (FEM). The arrangement effect of three needle-type applicators on the resultant thermal profiles and the volumes of ablation zones were analyzed and compared. In addition, the ablation zones for various angles of the RF applicator placed in the center of the tumor were analyzed. The paper shows that in order to control temperature distribution and ablation zones the proposed system of RF applicators and the arrangement of electrodes can be successfully applied in hepatocellular carcinoma treatment.
Przejdź do artykułu

Autorzy i Afiliacje

Piotr Gas
1
ORCID: ORCID
Arkadiusz Miaskowski
2
ORCID: ORCID

  1. Department of Electrical and Power EngineeringAGH University of Krakow30 Mickiewicza Ave., 30-059 Krakow, Poland
  2. Lublin University of TechnologyFaculty of Electrical Engineering and Computer Science38A Nadbystrzycka Str., 20-618 Lublin, Poland

Abstrakt

The technique of estimating the expected decrease in electricity consumption from the grid and using PV energy for the taken load schedule based on archival data for 5 years is refined. With full self-consumption (SC), the reduction of consumption from the grid can be increased by 9.5%–30.7% for a year according to the rated PV power. Consumption should increase when PV generation exceeds a certain value. A discrete time control of the power of an electric storage boiler (ESB) is proposed based on the deviation of the storage battery (SB) state of charge from a given schedule with a heating concentration during hours of high PV generation. In the considered application, it is possible to increase SC by up to 21%. Reducing the load in the evening allows us to use SB energy to reduce consumption from the grid at night. The possibility of complete photovoltaic SC when the ESB is used with an air conditioner is substantiated. Limitations for air conditioner energy consumption according to PV generation are determined. The system’s 24h model of energy processes is supplemented with a thermal model. The standard use of ESB with water temperature maintenance was also considered for comparison. ESB power control allows you to reduce daily energy consumption from the grid by 1.7–2 times. When combining an adjustable ESB with an air conditioner, it is possible to reduce consumption from the grid by 1.466–1.558 times at minimum and increase consumption from the grid by 2–5% at maximum air conditioner consumption.
Przejdź do artykułu

Autorzy i Afiliacje

Olexandr Shavolkin
1
ORCID: ORCID
Iryna Shvedchykova
1
ORCID: ORCID
Michal Kolcun
2
ORCID: ORCID
Dusan Medved
2
ORCID: ORCID
Damian Mazur
3
ORCID: ORCID
Bogdan Kwiatkowski
3
ORCID: ORCID

  1. Department of Computer Engineering and ElectromechanicsKyiv National University of Technologies and DesignMala Shyianovska 2, 01011, Kyiv, Ukraine
  2. Faculty of Electrical Engineering and Informatics, Technical University of KosiceLetná 9, 04200, Košice, Slovakia
  3. Department of Electrical and Computer Engineering FundamentalsRzeszow University of TechnologyPowstancow Warszawy 12, 35-959 Rzeszow, Poland

Abstrakt

In this paper, a Dual Second Order Generalized Integrator_Phase Locked Loop (DSOGI_PLL) technique applied to the Photovoltaic (PV) system supplying a Z-Source five-level Inverter (ZSI) is presented. The ZSI assures the increasing voltage of the PV system and provides the desired output DC at the input of the five-level Neutral Point Clamped Inverter (5L_NPCI), without any control which reduces the complexity of the overall system, this is due to the impedance network in its structure. We use Z-Source in order to eliminate the controlled DC bus as well as the use of the DC-DC Boost converter as an intermediary. A DSOGI technique is employed to control and optimize the energy quality, especially in distorted grid conditions and allows one to obtain a very low value of Total Harmonic Distortion (THD) which means lower peak currents, and higher efficiency. Low THD is an essential feature in power systems that international standards such as IEC 61000-3-2, and IEEE-519 set limits on the harmonic currents of various classes of power equipment connected to a distorted three-phase grid. Compared to the classic structure of inverters, the NPC five-level inverter presents a very high performance.
Przejdź do artykułu

Autorzy i Afiliacje

Ali Daoudi
1
ORCID: ORCID
Hocine Benalla
1
Khalil Nebti
1

  1. Département d’électrotechnique, laboratoire d’électrotechnique de ConstantineUniversité Constantine 1, 25000 Constantine, Algeria

Abstrakt

The natural mode of operation for the brushless doubly-fed induction machine is a particular instance of synchronism at a so-called natural rotor velocity when one stator winding is powered by an AC and the other by a DC voltage source. Consequently, in addition to the rotating magnetic field, there exists a magnetic field that is fixed to the stator frame of reference. Analysis in this specific mode is essential as the natural velocity arises from the choice of pole numbers, thereby determining machine efficiency. However, this presents a significant challenge when it comes to mathematical modeling using complex-valued steady-state models through either equivalent-circuit or finite element analysis. This paper presents a study on the extension of the recently-proposed steady-state complex-valued finite element model for the brushless doubly-fed induction machine to enable its application in the natural operating mode. A high correlation with the data obtained from a time-stepping model is obtained for the extended model when subjected to both low and high levels of saturation of the magnetic circuit. This extension makes the whole approach applicable in all operating conditions and modes of the brushless doubly-fed induction machine. Considering the nearly two orders of magnitude lower computational costs associated with analysis via the proposed model compared to time-stepping analysis, it is particularly useful in scenarios that involve extensive computations and require multiple cases to be considered such as design sensitivity analysis, topology optimization or a connection with machine learning techniques.
Przejdź do artykułu

Autorzy i Afiliacje

Mariusz Jagieła
1
Marian Łukaniszyn
1
ORCID: ORCID

  1. Opole University of Technology Faculty of Electrical Engineering, Automatic Control and Informatics 45-758 Opole, ul. Prószkowska 76

Abstrakt

Mechanisms of contact diffusion during relay-contacts operation were investigated. The contacts with the same geometry but different chemical composition were tested. The 1st relay-contact in a pair was made of copper, and the 2nd had a surface coated with a layer of silver about 500 micrometers thick. Different numbers of work cycles ranging from 8.5 k to 550 k were applied. AC current in the system was limited to 5 A. The closed/open periods were set at 250/250 ms. The resistance of the contacts was measured every 100 cycles. The microstructure of the working surfaces of the contacts after different numbers of operating cycles was investigated. On the surface of Cu contacts eutectic precipitates are formed and on the complementary bimetal contact tiny Cu-rich precipitates were generated on the silver surface. Crossection observations showed mutual material diffusion between the contacts. The depth of silver diffusion into the copper contact after 550 k operating cycles reaches 30 micrometers. The resistance of the contact system was stabilized after 40 k cycles at a level of 0.25 Ohm.
Przejdź do artykułu

Autorzy i Afiliacje

Agnieszka Hotlos
1
Grzegorz Boczkal
1
ORCID: ORCID
Marcin Karpinski
2

  1. AGH University of Krakow, Faculty of Non-Ferrous Metals Al. Mickiewicza 30, 30-059 Kraków, Poland
  2. Łukasiewicz Research Network – Institute of Non-Ferrous Metals Sowinskiego 5 St., 44-100 Gliwice, Poland

Abstrakt

The increasing demand for centralised power consumption in rural agriculture may result in low voltage and three-phase imbalance issues at the end of the distribution network. Furthermore, the extensive implementation of distributed photovoltaic (PV) systems may cause an imbalance between agricultural power load and PV output, exacerbating the issue of PV losses. In this paper, an optimal scheduling strategy for an integrated source-networkload- storage system is proposed to solve the above problems. The proposed strategy involves a dispatch model that includes PV power generation and energy storage, with the objective of maximising PV consumption and minimising operating costs. The PPO algorithm is finally employed to solve the cooperative optimisation model for source-grid-load-storage. The proposed scheduling strategy has been validated through examples, and the results demonstrate its effectiveness in ensuring the economic and safe operation of rural distribution networks.
Przejdź do artykułu

Autorzy i Afiliacje

Zhimin Lei
1
Qianwen Pei
1
Junrong Lian
1
Jinjin Song
2
ORCID: ORCID
Zhaoxu Zhang
1

  1. Baiyin Power supply company, State Grid Gansu Electric Power CompanyBaiyin 730900, China
  2. School of New Energy and Power Engineering, Lanzhou Jiaotong UnversityLanzhou 730070, China

Abstrakt

To convert photovoltaic arrays to solar energy in a more efficient way, this paper has proposed a maximum power point tracking controller model based on the chaotic quantum particle swarm-mothballing hybrid algorithm. First, the optimization of the particle swarm algorithm is designed to solve defects, such as premature maturity by using the quantum and chaotic strategies. The mothballing algorithm is introduced to help the model find global optimization-seeking more quickly. After that, further optimization was made to operate the tracking model in both offline and real-time parameters. The conductivity increment method and the perturbation observation method were adopted to effectively track the model under different temperatures and light intensities. Finally, the simulation and analysis experiments were carried out on the Simulink platform. The study’s proposed maximum power point tracking controller achieved a steady-state accuracy η2 of 99.84%. In summary, the study has proposed a hybrid intelligent algorithm with extraction of internal parameters. The maximum power point tracker based on the proposed method is proved to be both effective and accurate.
Przejdź do artykułu

Autorzy i Afiliacje

Zili Wang
1
Weilu Yuan
1

  1. College of Electromechanical EngineeringAnyang Vocational and Technical CollegeAnyang 455000, China

Abstrakt

In this article a control method for a rotor side converter (RSC) of a doubly fed induction generator of a wind turbine is developed. The doubly-fed induction generator (DFIG) system of a wind energy power plant that improves grid symmetrization was applied. The issue of optimal control was treated as an extended linear quadratic regulator (ELQR) having an extra set of exogenous inputs, which are source voltages of the electric grid. No additional knowledge of equations modelling the exogenous inputs was assumed. The proposed method is much more efficient than the currently available linear quadratic control methods. The control objective for a weak grid was to maintain the given value of the voltage module on load terminals and the given value of active power transferred from the stator’s winding. First harmonic components of relevant waveforms were used for this purpose. This task also required the DFIG system to provide reactive power to the grid. In the case of a rigid grid, this reactive power would be too high. Therefore, in this case, it was assumed that the system would supply only part of the required active and reactive power, based on its capabilities. It was required that the voltage and current ratings of the system, mainly the DFIG, were not exceeded. Therefore, the parameters of the network in these difficult failure cases were corrected only partially. The behaviour of the grid in the conditions of failure, as well as the return to the steady state after failure disappearance, were studied.
Przejdź do artykułu

Autorzy i Afiliacje

Marek Gołębiowski
1
ORCID: ORCID

  1. Department of Electrical and Computer Engineering Fundamentals, Rzeszow University of Technologyul. W. Pola 2, 35-959 Rzeszów, Poland

Abstrakt

With the wide application of smart meters, real-time data collection in power grid operation can be carried out in real time, which provides big data support for the digital modeling of distribution station areas. At the same time, the digital transformation of the distribution area can be promoted through the digital modeling of the distribution area. In this situation, how to use the big data of smart meters to achieve the digital modeling of the distribution area needs to be further studied. Firstly, this paper briefly introduces the connotation of digitalization in the distribution station area. At the same time, aiming at the digitalization of the distribution station area, it analyzes the digitalization of station features, user features, new energy features, network parameters and operation features, and obtains the digitalization model. Finally, on the basis of the above, select an application scenario to introduce the application of digitalization modeling. The research results can provide a reference for the combination of big data application of smart meters and digitalization of the distribution area, and help the digital transformation of the distribution area.
Przejdź do artykułu

Autorzy i Afiliacje

Hao Bai
1
Yu Fu
2
Weichen Yang
1
Yue Li
2
Yongxiang Cai
2
Min Xu
1

  1. Electric Power Research Institute, China South Power Grid, Ltd. Guangzhou, China
  2. Guizhou Power Grid Co. Ltd. Guiyang, China

Abstrakt

As we have known, permanent magnet synchronous motors (PMSMs) have garnered widespread interest across various industrial applications thanks to their advantages such as high efficiency, reliable performance, simple structure, and adaptability to various shapes and sizes. Due to characteristics of the high torque and low speed, the PMSMs make particularly well-suited for traction applications such as trucks, ship propulsion, mining, and more. In this context, a combination of the analytical method and finite element method (FEM) is proposed for designing and simulating a six-phase surface-mounted PMSM. Firstly, a model of the six-phase PMSM is analytically design to make required/main dimensions. The FEM is then applied to analyse and verify electromagnetic parameters such as of the current waveform, back electromagnetic force (EMF), magnetic flux density in the air gap, flux linkage, torque, cogging torque, torque ripple and harmonic components. Via the obtained results, the research will give a contribution of valuable insights for optimizing the design, performance and reliability for this motor in diverse industrial applications.
Przejdź do artykułu

Autorzy i Afiliacje

Vuong Dang Quoc
1 2
ORCID: ORCID
Trinh Truong Cong
1
ORCID: ORCID

  1. Laboratory of High Performance electric machines (HiPems) Vietnam
  2. School of Electrical and Electronic Engineering, Ha Noi University of Science and Technology Vietnam

Abstrakt

This work represents a moving fuzzy sliding mode controller (SMC) to suppress the wing-rock motion, a self-sustaining cycle oscillation caused by the nonlinear coupling between the unsteady aerodynamic forces and the dynamic response of the aircraft. Based on fuzzy systems, a moving algorithm is designed to estimate the unknown nonlinear dynamic function of the system in the control topology. The fuzzy algorithm is formulated by taking the width’s value, and based on Lyapunov theory, the membership function’s mean vector is adapted online. Simulation results, for examples that include small and large initial conditions, demonstrate the effectiveness of the proposed fuzzy sliding mode controller.
Przejdź do artykułu

Autorzy i Afiliacje

Sinda Aloui
1
Samia Larguech
2
Shabana Urooj
2
Norah Alwadai
3

  1. Laboratory of Sciences and Techniques of Automatic control computer engineering (Lab-STA) National School of Engineering of Sfax, University of Sfax Postal Box 1173, 3038 Sfax, Tunisia
  2. Department of Electrical Engineering, College of Engineering Princess Nourah bint Abdulrahman University Riyadh, Saudi Arabia
  3. Department of Physics, College of Sciences, Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia

Abstrakt

In European countries, electrified routes amount for 40% to 65% of the total railway networks length. Some of those routes are only partially electrified, and construction of a catenary network might not be viable on all routes. Consequently, operators run diesel trains under catenary or require both an electric and diesel vehicle, increasing costs of operation. Dual-mode vehicles exist, but they are mostly equipped with diesel generators, adding to the pollution and resulting in reduced movement dynamics. In this article, the authors present a hydrogen-hybrid electric multiple unit (HEMU), as an environmentally friendly vehicle for partially electrified railway lines. Insight into technologies utilized by both hybrid and hydrogen rail vehicles based on the literature review allowed for the formulation of requirements for such a vehicle. Furthermore, an approach to a modelling hybrid vehicle is described, including an energy management algorithm. A series of simulations were conducted, showing an operation of an HEMU on a partially electrified suburban/regional route. The presented simulation results show potential for the future introduction of hydrogen hybrid electric multiple units as a viable solution for partially electrified local and regional routes.
Przejdź do artykułu

Autorzy i Afiliacje

Aleksander Jakubowski
1
Lech Lipinski
2
Dawid Kwiatkowski
2
Dariusz Karkosinski
1
Natalia Karkosinska-Brzozowska
3

  1. Faculty of Electrical and Control Engineering, Gdansk University of TechnologyGabriela Narutowicza str., 11/12, 80-233 Gdansk, Poland
  2. PESA Bydgoszcz SA, Zygmunta Augusta str., 11, 85-082 Bydgoszcz, Poland
  3. Faculty of Civil and Environmental Engineering, Gdansk University of TechnologyGabriela Narutowicza str., 11/12, 80-233 Gdansk, Poland

Abstrakt

Two schemes have been developed to reduce the cogging torque generated by the gap between the stator modules of the modular permanent magnet synchronous motor. These schemes involve shifting the gap position to change the phase of the cogging torque, thereby eliminating some of its components and reducing its magnitude. Finite element simulation was used to verify the cogging torque of E and C type modular motors using two different schemes. The effect of the offset gap on electromagnetic performance and motor vibration noise was also analysed. The results indicate that both schemes weaken the cogging torque without significantly affecting the electromagnetic performance of the motor or increasing vibration noise.
Przejdź do artykułu

Autorzy i Afiliacje

Caixia Tao
1
Yaogeng Zhang
1
ORCID: ORCID
Fengyang Gao
1
ORCID: ORCID
Jiangang Zhang
2

  1. School of Automation and Electrical Engineering, Lanzhou Jiaotong UniversityGansu Province, China
  2. School of Mathematics and Science, Lanzhou Jiaotong University Gansu Province, China

Abstrakt

The use of the interior permanent magnet synchronous machine (IPMSM) drive has profoundly increased in a large number of applications due to numerous advantages. Owing to the disadvantages of mechanical sensors, sensorless control techniques are employed to enhance the performance of the IPMSM drive by removing the effect of noise and gain drift due to the sensor, increasing reliability, cost saving, and reducing overall size. This article presents the comparative analysis between the adaptive observer and non-adaptive extended electromotive force (EEMF) observer based on the active flux concept in a stationary reference frame (α–β). Moreover, the effect of slot harmonics and non-sinusoidal distribution of rotor flux is present in the three-phase IPMSM, this problem is considered as the control system disturbances in this article. Due to the non-sinusoidal distribution of flux and slot harmonics, the observer structure in the rotating reference frame (d–q) fails to estimate at the low-speed operation range. Comparative analysis between adaptive and non-adaptive observer structures is provided for a wide speed range. The effectiveness of the observer structures is examined using the classical field-oriented control scheme. In the end, simulation and experimental results are demonstrated to validate the performance of the sensorless control scheme using the adaptive and non-adaptive observer structures for the three-phase IPMSM drive setup.
Przejdź do artykułu

Autorzy i Afiliacje

Deepak Vyas
1
ORCID: ORCID
Marcin Morawiec
1
ORCID: ORCID
Tadele Ayana
1
ORCID: ORCID
Lelisa Wogi
1
ORCID: ORCID
Jarosław Guzinski
1
ORCID: ORCID

  1. Faculty of Electrical and Control Engineering, Gdansk University of Technology11/12 Narutowicza str., 80-233 Gdansk, Poland

Abstrakt

The paper presents an in-depth analysis of the power losses in the windings and the cores of two different transformers as applied to a phase-shifted full bridge (PSFB) converter at the power level of 20–25 kW and the switching frequency of 50 kHz. The main difference in the construction of the considered devices was the method of winding realization as well as the shape and material of the cores. The influence of the winding geometry on the conduction losses was analyzed, and the losses in the cores were analytically estimated, taking into account the operating conditions of these elements in the full-bridge system with phase-shift modulation. Original resistive models of windings made of cooper sheets are presented. The obtained results were verified by experimental tests carried out in an isolated full-bridge DC/DC converter.
Przejdź do artykułu

Autorzy i Afiliacje

Piotr Grzejszczak
1
ORCID: ORCID
Roman Barlik
1
ORCID: ORCID
Kornel Wolski
1
ORCID: ORCID

  1. Institute of Control and Industrial Electronics, Warsaw University of TechnologyKoszykowa 75, 00-662 Warszawa, Poland

Abstrakt

Hardware-in-loop (HIL) is a technique that allows one to simulate the behavior of a technical system in real time. This makes it a valuable tool for controller validation in many fields including photovoltaic systems. This paper proposes an experiment solution for maximizing power of the photovoltaic (PV) panel using HIL simulation. The proposed HIL configuration consists of two parts. The first part includes the PV, the DC-DC boost converter and load are simulated using HYPERSIM and run on the real-time OPAL-RT simulator. The second part is the real MPPT controller based on the perturbation and observation (P&O) algorithm for maximum power point tracking (MPPT) using the TMS320F28379D board. To evaluate the effectiveness of the proposed HIL configuration, the paper also presents a software-in-loop (SIL) simulation configuration for MPPT including the PV, the boost converter, load and MPPT controller based on the P&O algorithm which are simulated using HYPERSIM and run on the real-time OPAL-RT simulator. The obtained results by the proposed HIL configuration are compared with those gained by the SIL configuration on the A10J-S72-175 PV module under different irradiance and temperature levels. The obtained results show that the proposed HIL configuration can be used to perform MPPT experiments for PV under different environmental conditions. In addition, the compared results show that the proposed HIL configuration fulfills its usefulness for evaluating the practical MPPT controllers.
Przejdź do artykułu

Autorzy i Afiliacje

Hoai Phong Nguyen
1
ORCID: ORCID
Thuan Thanh Nguyen
1
ORCID: ORCID

  1. Faculty of Electrical Engineering Technology Industrial University of Ho Chi Minh City No. 12 Nguyen Van Bao, Ward 4, Go Vap District, Ho Chi Minh City, Vietnam

Instrukcja dla autorów

ARCHIVES OF ELECTRICAL ENGINEERING (AEE) (previously Archiwum Elektrotechniki), quarterly journal of the Polish Academy of Sciences is OpenAccess, publishing original scientific articles and short communiques from all branches of Electrical Power Engineering exclusively in English. The main fields of interest are related to the theory & engineering of the components of an electrical power system: switching devices, arresters, reactors, conductors, etc. together with basic questions of their insulation, ampacity, switching capability etc.; electrical machines and transformers; modelling & calculation of circuits; electrical & magnetic fields problems; electromagnetic compatibility; control problems; power electronics; electrical power engineering; nondestructive testing & nondestructive evaluation.

Manuscript submission:

All manuscripts should be submitted electronically on Editorial System.

Submission of paper to the Archives of Electrical Engineering is understood to imply that the article is original, unpublished and is not being considered for publication elsewhere. All articles will be reviewed. Since 2013, Authors wishing to use the facility of colour printing should consult the editors.

Template:

Microsoft Word is recommended as a standard word processor to prepare the paper to the AEE journal. If you use the LaTex format, please transfer your document to Microsoft Word and then use Template AEE.

While editing your paper, make sure that all the mathematical characters (symbols, identifiers, variables, vectors, axis marks, etc.) have the required shape, thickness, and slant kept throughout the whole article. The same appearance of a given mathematic character must be retained regardless of its place (text, equations, tables or figures).

The articles that don’t conform to the above will not be processed and published.

The reviewing process:

Each paper submitted for publication in Archives of Electrical Engineering is subjected to the following review procedure:

a) the paper is reviewed by the editor in chief or guest editor for general suitability for publication in AEE

b) if it is judged suitable two reviewers are selected and a double blind peer review process takes place

c) based on the recommendations of the reviewers, the editor then decides whether the paper should be accepted in its present form, revised or rejected

d) the author(s) is(are) informed by e-mail on the results of the reviewing procedure.

The papers are published on average within 3 months after acceptance.

Requirements for preparation of manuscripts:

The manuscript submitted for publication should have no less than 12 pages and no more than 16 pages. In the case of the manuscript longer than 16 pages, please contact the AEE Editorial Board before submitting your paper. The manuscripts, written in UK English, should be typed using Template AEE according to the following instructions and should include: a title page with the title of a manuscript, a short title; abstract; key words, text; list of references. A DOI number as well as received and revised data will be completed by Editor. When you open Template.doc, select "Print Layout" from the "View" menu in the menu bar (View > Print Layout). Then type over sections of Template.doc or cut and paste from another document and then use markup styles (Home > Styles). For example, the style at this point in the document is "main text").

All papers submitted for publication are assessed on the basis of the mutual anonymity rule as to the names of reviewers and authors. Authors' names and affiliations should not appear in the attached text/tables/figures.

If English is not your first language, ask an English-speaking colleague to proofread your manuscript. The manuscripts that fail to meet basic standards of literacy are likely to be immediately declined or after the language assessment, sent to the authors for linguistic improvement.

The manuscripts are published on average within 3 months after their acceptance.

Do not change the font sizes or line spacing to squeeze more text into a limited number of pages. Leave some open space around your figures.

The AEE journal publishes an ORCID for all authors. You will need a registered ORCID in order to submit your paper for peer review. ORCID registration is free and only takes a minute. Please note that ORCIDs will be added in the course of the author's proofreads.

Text:

The pages must be numbered consecutively. Articles should be divided into numbered sections, and if necessary subsections, preferably: Introduction, Material, Methods, Results, Conclusion and References. Any special characters (e.g. Greek, script, etc.) should be named in the margin where the character first occurs in the text. Names of species are to be accentuated with wavy underlining (italics). Equations should be numbered serially (1), (2), ... on the right side of the page. Footnotes should be avoided, if required, they should be used only for brief notes which do not fit well into the text. Figures and tables have to be included into the text. If table is typed on a separate page its position in the text should be marked. Abbreviations should be explained when they first appear in the text.

Math:

Please use the MathML editor as well as MathType editor to build an equation in your manuscript.

Equations:

Equations should be typed within the text, centred, and should be numbered consecutively throughout the text. Their numbers should be typed in parentheses, flush right. Equations should be referred to in text, e.g. (1), except at the beginning of a sentence: "Equation (1) is ...". All symbols appearing in equations have to be defined in the text, before or just after the equation.

If the symbols are written in Times New Roman use italic fonts. Symbols of vectors and matrices should be written in bold fonts. Do not italicize Greek fonts and mathematical symbols like e.g.: the derivative symbol d, max, min, etc. The indices of symbols that are indices themselves should be written in a clear manner.

Note that the equation is centered using a center tab stop. Please keep the same font in the formulas and text.

Unit Symbols, Abbreviations:

Define abbreviations and acronyms the first time they are used in the text, even after they have been defined in the abstract. Abbreviations such as IEEE, SI, MKS, CGS, sc, dc, and rms do not have to be defined. Do not use abbreviations in the title or heads unless they are unavoidable.

Si units are recommended for use in formulas, drawings and tables., for example the SI unit for magnetic field strength H is A/m. Apply the center dot to separate compound units.

Do not mix complete spellings and abbreviations of units: "Wb/m2" or "webers per square meter," not "webers/m2." Spell units when they appear in text: "...a few henries…", not "...a few H…".

Use a zero before decimal points: "0.25," not ".25." Use "cm3," not "cc."

Unit Symbols, SI Prefixes as well as Abbreviations should be writing in accordance with the IEEE standard

Tables, figures (illustrations) and captions:

The illustrations (line diagrams and photographs) should be suitable for direct reproduction. The lettering as well the details should have proportional dimensions to maintain their legibility after the usual reduction. All illustrations should be numbered consecutively (Fig. X). Tables are numbered with Arabic numerals.

All figures, figure captions, and tables in the text must be inserted into the correct places.

Figures, photos, tables or other parts of a manuscript that have previously appeared in another publication or are not the property of the authors must be properly acknowledged in the manuscript. Permission to republish these items must be obtained by the corresponding author from a person or institution holding the copyright, usually the publisher.

Authors are requested to send all drawings used in the article in additional files. Create a separate file for each image. Images should be submitted in a bitmap format (.jpeg) or/and in a vector format (.eps, .pdf or .cdr). Each file must be saved according to the number in the original article, e.g.: FIG1.JPG, FIG2.EPS, or FIG3.PDF. Bitmap illustrations must be “flattened”, which means no additional layers, for example, covering old descriptions.

Photographs, colour, and greyscale figures should be at least at a resolution of 400 dpi.

All colour figures should be generated in the RGB or CMYK colour space, while greyscale images in the greyscale colour space.

When preparing your figures/graphics etc., we suggest the use of the Arial 8 point font for axis numbers and Arial 9 point font for axis names. Figures/graphics etc. can be prepared in one of two proposed ways - see Template AEE.

Tables are numbered with Arabic numerals. Use 9 point Times New Roman for the title of the table and 9 point Times New Roman for the filling of the table (9 in the case of symbols with subscripts).

AEE journal allows an author to publish color figures in e-version at no charge, and automatically convert them to grayscale for print versions. Authors wishing to use the facility of color printing should consult the editors.

Conclusions:

A conclusion might elaborate on the importance of the work or suggest applications and extensions. Although a conclusion may review the main points of the manuscript, do not replicate the abstract as the conclusion.

References:

References in text must be numbered consecutively by Arabic numerals placed in square brackets. Please make sure that you use full names of journals i.e. Archives of Electrical Engineering. Please ensure that all references in the Reference list are cited in the text and vice versa.

Please provide name(s) and initials of author(s), the title of the manuscript, editors (if any), the title of the journal or book, a volume number, the page range, and finally the year of publication in brackets.

You can use the rules presented on the site: IEEE standard.

Examples of the ways in which references should be cited are given below:

Journal manuscript

[1] Author1 A., Author2 A., Title of paper, Title of periodical, vol. x, no. x, pp. xxx-xxx (YEAR).

example

[1] Steentjes S., von Pfingsten G., Hombitzer M., Hameyer K., Iron-loss model with consideration of minor loops applied to FE-simulations of electrical machines, IEEE Transactions on Magnetics. vol. 49, no. 7, pp. 3945-3948 (2013).

[2] Idziak P., Computer Investigation of Diagnostic Signals in Dynamic Torque of Damaged Induction Motor, Electrical Review (in Polish), to be published.

[3] Cardwell W., Finite element analysis of transient electromagnetic-thermal phenomena in a squirrel cage motor, submitted for publication in IEEE Transactions on Magnetics.

Conference manuscript

[4] Author A., Title of conference paper, Unabbreviated Name of Conf., City of Conf., Country of Conf., pp. xxx-xxx (YEAR).

example

[4] Popescu M., Staton D.A., Thermal aspects in power traction motors with permanent magnets, Proceedings of XXIII Symposium Electromagnetic Phenomena in Nonlinear Circuits, Pilsen, Czech Republic, pp. 35-36 (2016).

Book, book chapter and manual

[5] Author1 A., Author2 A.B., Title of book, Name of the publisher (YEAR).

example

[5] Zienkiewicz O., Taylor R.L., Finite Element method, McGraw-Hill Book Company (2000).

Patent

[6] Author1 A., Author2 A., Title of patent, European Patent, EP xxx xxx (YEAR).

example

[6] Piech Z., Szelag W., Elevator brake with magneto-rheological fluid, European Patent, EP 2 197 774 B1 (2011).

Thesis

[7] Author A., Title of thesis, PhD Thesis, Department, University, City of Univ. (YEAR).

example

[7] Driesen J., Coupled electromagnetic-thermal problems in electrical energy transducers, PhD Thesis, Faculty of Applied Science, K.U. Leuven, Leuven (2000).

For on electronic forms

[8] Author A., Title of article, in Title of Conference, record as it appears on the copyright page], © [applicable copyright holder of the Conference Record] (copyright year), doi: [DOI number].

example

[8] Kubo M., Yamamoto Y., Kondo T., Rajashekara K., Zhu B., Zero-sequence current suppression for open-end winding induction motor drive with resonant controller,in IEEE Applied Power Electronics Conference and Exposition (APEC), © APEC (2016), doi: 10.1109/APEC.2016.7468259

Website

[9] http://www.aee.put.poznan.pl, accessed April 2010.

Proofs:

Authors will receive proofs for correction, which should be returned promptly. All joint contributions must indicate the name and address of the authors to whom proofs should be sent.

Fees for printing the papers in Archives of Electrical Engineering:

AEE is published in Open Access, which means that all articles are available on the internet to all users immediately upon publication free of charge for the readers. Authors will be asked to a declaration that they are ready to cover the costs of printing their article.

The fee for the publication of an article in the AEE journal is 200 Euro.

Abstracting & Indexing:

Archives of Electrical Engineering is covered by the following services:

  • Arianta
  • Baidu Scholar
  • BazTech
  • Celdes
  • CNKI Scholar (China National Knowledge Infrastucture)
  • CNPIEC
  • DOAJ
  • EBSCO - TOC Premie
  • EBSCO (relevant databases)
  • EBSCO Discovery Service
  • Elsevier - Compendex
  • Elsevier - Engineering Village
  • Elsevier - SCOPUS
  • Genamics JournalSeek
  • Google Scholar
  • ICI Journals Master List
  • Inspec
  • J-Gate
  • Naviga (Softweco)
  • POL-Index
  • Primo Central (ExLibris)
  • ProQuest - Advanced Technologies Database with Aerospace
  • ProQuest - Electronics and Communications Abstracts
  • ProQuest - Engineering Journals
  • ProQuest - High Tech Research Database
  • ProQuest - Illustrata: Technology
  • ProQuest - SciTech Journals
  • ProQuest - Technology Journals
  • ProQuest - Technology Research Database
  • SCImago (SJR)
  • Summon (Serials Solutions/ProQuest)
  • TDOne (TDNet)
  • TEMA Technik und Management
  • Thomson Reuters - Emerging Sources Citation Index
  • Ulrich's Periodicals Directory/ulrichsweb
  • WorldCat (OCLC)

Preparation of manuscript for Archives of Electrical Engineering (AEE)

AEE License to publish

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji