Applied sciences

Metrology and Measurement Systems

Content

Metrology and Measurement Systems | 2019 | vol. 26 | No 1

Download PDF Download RIS Download Bibtex

Abstract

The main points of the UPoN-2018 talk and some valuable comments from the Audience are briefly summarized. The talk surveyed the major issues with the notion of zero-point thermal noise in resistors and its visibility; moreover it gave some new arguments. The new arguments support the old view of Kleen that the known measurement data “showing” zero-point Johnson noise are instrumental artifacts caused by the energy-time uncertainty principle. We pointed out that, during the spectral analysis of blackbody radiation, another uncertainty principle is relevant, that is, the location-momentum uncertainty principle that causes only the widening of spectral lines instead of the zero-point noise artifact. This is the reason why the Planck formula is correctly confirmed by the blackbody radiation experiments. Finally a conjecture about the zero-point noise spectrum of wide-band amplifiers is shown, but that is yet to be tested experimentally.

Go to article

Authors and Affiliations

Laszlo B. Kish
Download PDF Download RIS Download Bibtex

Abstract

Low-frequency noise measurements have long been recognized as a valuable tool in the examination of quality and reliability of metallic interconnections in the microelectronic industry. While characterized by very high sensitivity, low-frequency noise measurements can be extremely time-consuming, especially when tests have to be carried out over an extended temperature range and with high temperature resolution as it is required by some advanced characterization approaches recently proposed in the literature. In order to address this issue we designed a dedicated system for the characterization of the low-frequency noise produced by a metallic line vs temperature. The system combines high flexibility and automation with excellent background noise levels. Test temperatures range from ambient temperature up to 300◦C. Measurements can be completely automated with temperature changing in pre-programmed steps. A ramp temperature mode is also possible that can be used, with proper caution, to virtually obtain a continuous plot of noise parameters vs temperature.

Go to article

Authors and Affiliations

Graziella Scandurra
Sofie Beyne
Gino Giusi
Carmine Ciofi
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a proposal of using additional statistical parameters such as: standard deviation, variance, maximum and minimum increases of the observed value that were determined during measurements of temperature fields created on the surface of the tested electrochemical capacitor. The measurements were carried out using thermographic methods in order to support assessment of the condition of electrochemical capacitor under classic durability tests based on methods of determination of capacity and equivalent series resistance. The possibility of using some statistical parameters in assessment of the electrochemical capacitor quality was illustrated. The applied measurement methodology and the results of research associated with the classic methods of supercapacitors’ assessment are presented. The obtained results indicate that the variability of some statistical parameters of temperature fields can be directly related to changing the values of standard parameters describing electrochemical capacitor, which are capacitance and equivalent series resistance.

Go to article

Authors and Affiliations

Stanisław Galla
Arkadiusz Szewczyk
Łukasz Lentka
Download PDF Download RIS Download Bibtex

Abstract

The Kirchhoff-law-Johnson-noise (KLJN) secure key exchange scheme offers unconditional security, however it can approach the perfect security limit only in the case when the practical system’s parameters approach the ideal behavior of its core circuitry. In the case of non-ideal features, non-zero information leak is present. The study of such leaks is important for a proper design of practical KLJN systems and their privacy amplifications in order to eliminate these problems.

Go to article

Authors and Affiliations

Mutaz Y. Melhem
Laszlo B. Kish
Download PDF Download RIS Download Bibtex

Abstract

Compact radiators with circular polarization are important components of modern mobile communication systems. Their design is a challenging process which requires maintaining simultaneous control over several performance figures but also the structure size. In this work, a novel design framework for multi-stage constrained miniaturization of antennas with circular polarization is presented. The method involves se- quential optimization of the radiator in respect of selected performance figures and, eventually, the size. Optimizations are performed with iteratively increased number of design constraints. Numerical efficiency of the method is ensured using a fast local-search algorithm embedded in a trust-region framework. The proposed design framework is demonstrated using a compact planar radiator with circular polarization. The optimized antenna is characterized by a small size of 271 mm2 with 37% and 47% bandwidths in respect of 10 dB return loss and 3 dB axial ratio, respectively. The structure is benchmarked against the state-of-the-art circular polarization antennas. Numerical results are confirmed by measurements of the fabricated antenna prototype.

Go to article

Authors and Affiliations

Adrian Bekasiewicz
Slawomir Koziel
Download PDF Download RIS Download Bibtex

Abstract

This paper describes a synthetic aperture radar system for tactical-level imagery intelligence installed on board an unmanned aerial vehicle. Selected results of its tests are provided. The system contains interchange-able S-band and Ku-band linear frequency-modulated, continuous wave radar sensors that were built within a frame of a research project named WATSAR, conducted by the Military University of Technology and WB Electronics S.A. One of several algorithms of radar image synthesis, implemented in the scope of the project, is described in this paper. The WATSAR system can create online and off-line radar images.

Go to article

Authors and Affiliations

Piotr Kaniewski
Wojciech Komorniczak
Czesław Leśnik
Jacek Cyrek
Waldemar Susek
Piotr Serafin
Michał Łabowski
Download PDF Download RIS Download Bibtex

Abstract

Malignant melanomas are the most deadly type of skin cancer, yet detected early have high chances of successful treatment. In the last twenty years, the interest in automatic recognition and classification of melanoma dynamically increased, partly because of appearing public datasets with dermatoscopic images of skin lesions. Automated computer-aided skin cancer detection in dermatoscopic images is a very challenging task due to uneven sizes of datasets, huge intra-class variation with small interclass variation, and the existence of many artifacts in the images. One of the most recognized methods of melanoma diagnosis is the ABCD method. In the paper, we propose an extended version of this method and an intelligent decision support system based on neural networks that uses its results in the form of hand-crafted features. Automatic determination of the skin features with the ABCD method is difficult due to the large diversity of images of various quality, the existence of hair, different markers and other obstacles. Therefore, it was necessary to apply advanced methods of pre-processing the images. The proposed system is an ensemble of ten neural networks working in parallel, and one network using their results to generate a final decision. This system structure enables to increase the efficiency of its operation by several percentage points compared with a single neural network. The proposed system is trained on over 5000 and tested afterwards on 200 skin moles. The presented system can be used as a decision support system for primary care physicians, as a system capable of self-examination of the skin with a dermatoscope and also as an important tool to improve biopsy decision making.

Go to article

Authors and Affiliations

Michał Grochowski
Agnieszka Mikołajczyk
Arkadiusz Kwasigroch
Download PDF Download RIS Download Bibtex

Abstract

In this paper the authors propose a decision support system for automatic blood smear analysis based on microscopic images. The images are pre-processed in order to remove irrelevant elements and to enhance the most important ones – the healthy blood cells (erythrocytes) and the pathologic ones (echinocytes). The separated blood cells are analysed in terms of their most important features by the eigenfaces method. The features are the basis for designing the neural network classifier, learned to distinguish between erythrocytes and echinocytes. As the result, the proposed system is able to analyse the smear blood images in a fully automatic way and to deliver information on the number and statistics of the red blood cells, both healthy and pathologic. The system was examined in two case studies, involving the canine and human blood, and then consulted with the experienced medicine specialists. The accuracy of classification of red blood cells into erythrocytes and echinocytes reaches 96%.

Go to article

Authors and Affiliations

Michał Grochowski
Michał Wąsowicz
Agnieszka Mikołajczyk
Mateusz Ficek
Marek Kulka
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a method of obtaining short-termpositioning accuracy based on micro electro-mechanical system (MEMS) sensors and analysis of the results. A high-accuracy and fast-positioning algorithm must be included due to the high risk of accidents in cities in the future, especially when autonomous objects are taken into account. High-level positioning systems should consider a number of sub-systems such as global positioning system (GPS), CCTV – video analysis, a system based on analysis of signal strength of access points (AP), etc. Short-term positioning means that there are other locating systems with a sufficiently high degree of accuracy based on, e.g. a video camera, but the located object can disappear when it is hidden by other objects, e.g. people, things, shelves etc. In such a case, MEMS sensors can be employed as a positioning system. The paper examines typical movement profiles of a radio-controlled (RC) model and fundamental filtering methods in respect of position accuracy. The authors evaluate the complexity and delay of the filter and the accuracy of the positioning in respect of the current speed and phase of movement (positive acceleration, constant) of the object. It is necessary to know whether and how the length of the filter changes the position accuracy. It has been shown that the use of fundamental filters, which provide solutions in a short time, enables to locate objects with a small error in a limited time.

Go to article

Authors and Affiliations

Damian Grzechca
Krzysztof Paszek
Download PDF Download RIS Download Bibtex

Abstract

A revision of the standard approach to characterization of thin-semiconductor-layer Hall samples has been proposed. Our results show that simple checking of I(V) curve linearity at room temperature might be insufficient for correct determination of bias conditions of a sample before measurements of Hall effect. It is caused by the nonlinear behaviour of electrical contact layers, which should be treated together with the tested layer a priori as a metal-semiconductor-metal (MSM) structure. Our approach was examined with a Be-doped p-type InAs epitaxial layer, with four gold contacts. Despite using full high-quality photolithography a significant asymmetry in maximum differential resistance (Rd) values and positions relative to zero voltage (or current) value was observed for different contacts. This suggests that such characterization should be performed before each high-precision magneto-transport measurement in order to optimize the bias conditions.

Go to article

Authors and Affiliations

Andrzej Kowalewski
Jarosław Wróbel
Jacek Boguski
Kinga Gorczyca
Piotr Martyniuk
Download PDF Download RIS Download Bibtex

Abstract

In this paper, we propose and experimentally demonstrate a new method for optical frequency transfer over fibre. Instead of dual acousto-optic modulators (AOMs) as adopted in the traditional fibre phase noise compensation setup, here an active fibre phase noise compensation scheme with a single acousto-optic modulator (AOM) is used. The configuration simplifies the equipment of the user end while maintaining a high-performance optical frequency transfer stability. We demonstrate an actively stabilized coherent transfer at an optical frequency of 193.55THz over 10-km spooled fibre, obtaining a relative frequency stability (Allan deviation) of 3.84 × 10−16/1 s and 4.08 × 10−18/104 s, which is improved by about 2∼3 orders of magnitude in comparison with the one without any phase noise compensation that achieves a relative frequency stability of 1.81 × 10−14/1 s and 2.48 × 10−15/104 s.

Go to article

Authors and Affiliations

Guoyong Wang
Yuanbo Yao
Tao Yan
Lang Bian
Yansong Meng
Download PDF Download RIS Download Bibtex

Abstract

Many researchers have contributed to creating Quantum Key Distribution (QKD) since the first protocol BB84 was proposed in 1984. One of the crucial problems in QKD is to guarantee its security with finite-key lengths by Privacy Amplification (PA). However, finite-key analyses show a trade-off between the security of BB84 and the secure key rates. This study analyses two examples to show concrete trade-offs. Furthermore, even though the QKD keys have been perceived to be arbitrarily secure, this study shows a fundamental limitation in the security of the keys by connecting Leftover Hash Lemma and Guessing Secrecy on the QKD keys.

Go to article

Authors and Affiliations

Takehisa Iwakoshi
Download PDF Download RIS Download Bibtex

Abstract

In recent years, many scientific and industrial centres in the world developed virtual reality systems or laboratories. At present, among the most advanced virtual reality systems are CAVE-type (Cave Automatic Virtual Environment) installations. Such systems usually consist of four, five, or six projection screens arranged in the form of a closed or hemi-closed space. The basic task of such systems is to ensure the effect of user “immersion” in the surrounding environment. The effect of user “immersion” into virtual reality in such systems is largely dependent on optical properties of the system, especially on quality of projection of three-dimensional images. In this paper, techniques of projection of three-dimensional (3D) images in CAVE-type virtual reality systems are analysed. The requirements of these techniques for such virtual reality systems are outlined. Based on the results of measurements performed in a unique CAVE-type virtual reality laboratory equipped with two different 3D projection techniques, named Immersive 3D Visualization Lab (I3DVL), that was recently opened at the Gdańsk University of Technology, the stereoscopic parameters and colour gamut of Infitec and Active Stereo stereoscopic projection techniques are examined and discussed. The obtained results enable to estimate the projection system quality for application in CAVE-type virtual reality installations.

Go to article

Authors and Affiliations

Adam Mazikowski
Download PDF Download RIS Download Bibtex

Abstract

In this paper we describe our own construction of a tuneable light source based on a set of light emitting diodes covering the visible spectrum using a homogenizing rod instead commonly used low energy-efficient integrating spheres. The expected prime application of the source is a medical endoscopic system, however it is possible to use it also for other purposes requiring both multispectral operation and a tuneable white light source. We describe the construction of the source and include precise characterization of the output white light – distribution of CCT, Duv, Δu′ v ′ and colour rendering indexes (Ra, R9, Rf , Rg) of light in several planes located at various distances. The obtained results prove that our source is characterized by very good colour rendition according to the Ra and Rf method for various correlated colour temperatures (2700–6500) K. As an example of application images of the Macbeth colour chart registered with an RGB camera included in the laboratory measurement stand are presented. The obtained results prove that, after whole system calibration, this source can be used in many applications, where evaluation of objects requires precise analysis of their colour and multispectral procedures.

Go to article

Authors and Affiliations

Urszula J. Błaszczak
Łukasz Gryko
Andrzej S. Zając
Download PDF Download RIS Download Bibtex

Abstract

According to metrological guidelines and specific legal requirements, every smart electronic electricity meter has to be constantly verified after pre-defined regular time intervals. The problem is that in most cases these pre-defined time intervals are based on some previous experience or empirical knowledge and rarely on scientifically sound data. Since the verification itself is a costly procedure it would be advantageous to put more effort into defining the required verification periods. Therefore, a fixed verification interval, recommended by various internal documents, standardised evaluation procedures and national legislation, could be technically and scientifically more justified and consequently more appropriate and trustworthy for the end user. This paper describes an experiment to determine the effect of alternating temperature and humidity and constant high current on a smart electronic electricity meter’s measurement accuracy. Based on an analysis of these effects it is proposed that the current fixed verification interval could be revised, taking into account also different climatic influence. The findings of this work could influence a new standardized procedure in respect of a meter’s verification interval.

Go to article

Authors and Affiliations

Blaž Radej
Janko Drnovšek
Gaber Begeš
Download PDF Download RIS Download Bibtex

Abstract

Reliable estimation of longitudinal force and sideslip angle is essential for vehicle stability and active safety control. This paper presents a novel longitudinal force and sideslip angle estimation method for four-wheel independent-drive electric vehicles in which the cascaded multi-Kalman filters are applied. Also, a modified tire model is proposed to improve the accuracy and reliability of sideslip angle estimation. In the design of longitudinal force observer, considering that the longitudinal force is the unknown input of the electric driving wheel model, an expanded electric driving wheel model is presented and the longitudinal force is obtained by a strong tracking filter. Based on the longitudinal force observer, taking into consideration uncertain interferences of the vehicle dynamic model, a sideslip angle estimation method is designed using the robust Kalman filter and a novel modified tire model is proposed to correct the original tire model using the estimation results of longitudinal tire forces. Simulations and experiments were carried out, and effectiveness of the proposed estimation method was verified.

Go to article

Authors and Affiliations

Long Chen
Te Chen
Xing Xu
Yingfeng Cai
Haobin Jiang
Xiaoqiang Sun

Instructions for authors



Sample article with Author guidelines



Author guidelines



Types of contributions

Metrology and Measurement Systems welcomes submissions of the following article types:

• invited special issue or review papers presenting the current stage of the knowledge within scope of the journal (about 20 edited pages, approximately 3000 characters each),
• research papers reporting high-quality original scientific or technological advancements (max. 12 pages),
• papers based on extended and updated contributions presented at scientific conferences (max. 12 pages),
• short notes, i.e. book reviews, conference reports, short news (max. 2 pages).


Manuscript preparation

General The text of a manuscript should be written in clear and concise English. The camera-ready format – with attached separate files containing illustrations, tables and photographs – is required. A cover letter with clear explanation of scientific novelty of the paper is strongly recommended. Papers based on extended and updated contributions presented at scientific conferences, or strongly related to previous authors’ works, must be accompanied with a cover letter file, which should explain in details changes made in the manuscript in comparison with the original conference paper and highlight the novelty in reference to other authors’ works.
The main text of a manuscript should be printed on an A4 page (with margins of 2.5 cm) using Times New Roman style with a font size of 12 pt; the paragraphs should start with the indentation of 5 mm, and titles should be written in bold. That text can be divided into sections (numbered 1, 2, …), first-order subsections (numbered 1.1., 1.2., …, written in italics), and – if needed – second-order subsections (numbered 1.1.1., 1.1.2., …, written same as first-order subsections). The only acceptable manuscript formats are in Microsoft Word (.doc, .docx).

The Editor encourages the Authors of submitted papers who are not English native speakers, to use a language service checking the language correctness not only with respect to grammar, but also in the way of presentation of research results accepted by renowned publishers, e.g. presented on the website of the European Association of Science Editors. The Editor encourages the Authors of submitted papers who are not English native speakers, to use a language service checking the language correctness not only with respect to grammar, but also in the way of presentation of research results accepted by renowned publishers, e.g. presented on the website of the European Association of Science Editors.


Figures
Figures (illustrations, photographs) and tables, provided in the camera-ready form suitable for reproduction (which may include reduction), should be additionally submitted (one per page), larger than the final size. While preparing figures we encourage to start with defining expected size and minimum font size that fit to all graphics in the manuscript – using the same style in all of your graphics visually improves the article. Final figure formats must be in one of the following: (vectors) .eps, .pdf, .ai or .cdr, and (bitmaps) .bmp, .gif, .tif or .jpg.
As far as plots, block diagrams, schematics etc. are concerned, we suggest to use one of vector formats to improve quality and scalability. Figures in vector formats must be saved using RGB colours and with fully white background (0% K). Hidden layers are unacceptable. Minimum line thickness printed in a single colour is 0.25 pt (0.09 mm), and 1 pt (0.36 mm) when using more colours. Typically we suggest 0.2-0.5 mm but in particular cases the range 0.1–1.0 mm will be accepted. Lines in plots should be distinguished not only by using different colours but also using different line types and markers, if needed.


Equation
All equations must be numbered consecutively throughout the text. Each equation should be preceded and followed by a 6-point spacing. Punctuate equations when they are part of a sentence. Equation numbers should be enclosed in parentheses. Equations should be prepared with the use of MathType or Microsoft Equation editors. The type size in the equation is the same as for the text. To make your equations more compact, you may use the appropriate mathematical symbols or expressions. The symbols used in an equation have to be defined before that equation or immediately after it. Use italics for variables (e.g. i, x, n), physical quantity symbol (e.g. voltage U, temperature T), letter pointers and general function symbols. Do not use italics for constants, indexes, minimum, maximum and trigonometric functions, mathematical operators, differentials, etc. To refer to the equation use “(1)”, not “Eq. (1)” or “equation (1)”, except at the beginning of a sentence where “Equation (1)” should be used. We recommend to use International System of Units SI i.e. metre-kilogram-second system of units. As a decimal separator dot should be used in the entire manuscript (text, figures, tables).


References
The paper has to be clearly positioned in the context of relevant literature in the field of measurements and instrumentation. Note that lack of references from the main field of Metrology and Measurement Systems interest may suggest that the content of manuscript does not exactly correspond to the scope of metrological journals. It may reduce possibility that a proposed paper will be read by audience society. In such a case our Editorial Board may suggest to send the manuscript to a more appropriate journal. Also note that the use of possibly up-to-date references may indicate importance of your work. Table below gives examples of some relevant and renewable journals related to widely understood metrology.


Journal

Publisher

ISSN

Metrologia

IOP Publishing

0026-1394

IEEE Transactions on Instrumentation and Measurement

IEEE

0018-9456

Measurement

Elsevier

0263-2241

Measurement Science and Technology

IOP Publishing

0957-0233

Metrology and Measurement Systems

PAS

0860-8229

Review of Scientific Instruments

IOP Publishing

0034-6748

IEEE Transactions on Industrial Electronics

IEEE

1557-9948

IET Science, Measurement & Technology

IET

1751-8822

Journal of Instrumentation

SISSA, IOP Publishing

1748-0221

Measurement Science Review

Walter de Gruyter

1335-8871

IEEE Instrumentation and Measurement Magazine

IEEE

1094-6969

Bulletin of the Polish Academy of Sciences: Technical Sciences

PAS

2300-1917

Opto-Electronics Review

PAS

1896-3757

IEEE Sensors Journal

IEEE

1558-1748

Sensors

MDPI

1424-8220




References should be inserted in the text in square brackets, i.e. [1]; their list, numbered in citation order, should appear at the end of the manuscript. The format of the references should follow the APA 7th edition formatting style, i.e.: for an journal paper – surname(s) and initial(s) of author(s), year in brackets, title of the paper, full journal name, volume, issue (in brackets) and page numbers. Put all author names unless there are more than 20. Otherwise, after the first 19 authors’ names, use an ellipsis in place of the remaining author names. Then, end with the final author’s name (do not place an ampersand before it).


Submission process
Manuscript should be submitted via the Internet Editorial System (IES) – an online submission and peer review system. In order to submit the manuscript via the IES, the authors (first-time users) must create an author account to obtain a user ID and password required to enter the system. The submission of the manuscript in a single file, i.e. “Article File” containing the complete manuscript (with all figures of high quality and tables embedded in the text), is preferred. All figures have to be uploaded in separate files. The generated PDF file has to be approved. The PDF file has lower quality of the embedded figures to limit its size only.
The submission of a manuscript means that its content has not been published previously, it is not under consideration for publication elsewhere, and that – if accepted – it will not be published elsewhere. The Author hereby grants the Polish Academy of Sciences (the Journal Owner) the license for commercial use of the article according to the Open Access License ( CC BY-NC-ND 4.0), which has to be signed before publication. The copyright form is available in the IES.
The Authors are urged to suggest 4 to 5 reviewers in their application (with names, affiliations and addresses) with whom the Editorial Board could co-operate while processing the paper. Proposed reviewers should be experts deeply involved in issues related to the subject matter of the paper and they are intended to come from different universities or research centres.
Each submitted manuscript is subject to a single-blind peer-review procedure, and the publication decision is based on the reviewers’ comments. If necessary, the authors may be invited to revise their manuscripts. On acceptance, manuscripts are subject to editorial amendment to exactly fit the journal style.
An essential criterion for the evaluation of submitted manuscripts is their potential impact on the research field, measured by the number of repeated quotations. Such papers are preferred at the evaluation and publication stages.
Proofs will be sent to the corresponding author by e-mail and should be returned within 48 hours from receipt. The publication in the journal is free of charge. A sample copy of the journal will be sent to the corresponding author free of charge. For colour pages the authors will be charged at the rate of 160 PLN or 80 EUR per page. The payment to the bank account of the main distributor (given in “Subscription Information”) must be completed before the date indicated by the Editorial Office.


Other information
It is possible to include supplementary files related to the article content, such as e.g. developed databases. These files can be then used by other researchers to compare their algorithms using the same input data. For more details about supplementary files please contact the Editorial Board: metrology@wat.edu.pl. The biographical statements, at the very end of the article, are not obligatory, however, they are kindly recommended. Each statement should include the author’s full name and brief personal history focused on areas of research and scientific achievements. The biographical statement may not exceed 100 words and should be written using Times New Roman style with a font size of 8 pt.
The publication of your article is a great achievement but then it needs to be further promoted to make it more visible to the research community. Responsibility for this task lies with the Authors and our Editorial Board. We guarantee free access to the article in the Journals PAN of the Polish Academy of Science, including articles in Early Access form (published just after acceptance decision), indexing in popular and renewable databases (e.g. Thomson Scientific Master Journal List, Elsevier’s Scopus, Google Scholar). Furthermore, selected articles are highlighted on the journal website and are reprinted for promotion at conferences and other events. The Authors can share the final form of the article on various social networks and research-sharing platforms, such as Twitter, Facebook, Linkedin, ResearchGate, Academia.edu, SciProfiles. They are also encouraged to update personal and institutional webpages by adding the title and a link of the article. Feel free also to share your work with your colleagues using any other methods that do not conflict with the CC BY-NC-ND 4.0 license.
For more detailed description about how to write a paper for the Metrology and Measurement Systems journal please look at the Author guidelines for manuscript preparation. We strongly recommend using this file as a template for manuscript preparation.


This page uses 'cookies'. Learn more